18. ADJUSTMENT AND SAFETY DEVICES
7KHERLOHUKDVEHHQGHVLJQHGLQIXOOFRPSOLDQFHZLWK(XURSHDQUHIHUHQFHVWDQGDUGVDQGLQSDUWLFXODULVHTXLSSHGZLWKWKHIROORZLQJ
Safety thermostat
7KLVGHYLFHKDVDVHQVRUSRVLWLRQHGRQWKHOHIWVHFWLRQRIWKHÀXHH[WUDFWLRQKRRGDQGVKXWVRIIWKHJDVÀRZWRWKHEXUQHULIWKH
ÀXHGXFWLVREVWUXFWHGRULQWKHHYHQWRIGUDXJKWIDLOXUH
It is forbidden to disable this safety device
NTC fumes probe
7KLVGHYLFHLVSRVLWLRQHGRQWKHIXPHVZDWHUH[FKDQJHU7KHHOHFWURQLFERDUGVWRSVJDVIURPÀRZLQJWRWKHEXUQHULQFDVHRIRYHU
heating.
7KHDERYHUHVHWRSHUDWLRQLVRQO\SRVVLEOHLIWKHWHPSHUDWXUHLVOHVVWKDQ&
It is forbidden to disable this safety device
Flame ionisation detector
7KHÀDPHVHQVLQJHOHFWURGHJXDUDQWHHVVDIHW\RIRSHUDWLRQLQFDVHRIJDVIDLOXUHRULQFRPSOHWHLJQLWLRQRIWKHPDLQEXUQHU,Q
these conditions, the boiler blocks.
+\GUDXOLFSUHVVXUHVZLWFK
7KLVGHYLFHDOORZVWKHPDLQEXUQHUWREHLJQLWHGRQO\LIV\VWHPSUHVVXUHLVKLJKHUWKDQEDUV
Pump post-circulation
The electronically-controlled pump post-circulation function lasts 3 minutes and is enabled, in the heating mode, if the ambient
thermostat causes the main burner to go out.
)URVWSURWHFWLRQGHYLFH
7KHHOHFWURQLFERLOHUPDQDJHPHQWV\VWHPLQFOXGHVDIURVWSURWHFWLRQIXQFWLRQIRUWKHKHDWLQJDQG'+:V\VWHPVZKLFKZKHQ
ÀRZWHPSHUDWXUHIDOOVEHORZ&RSHUDWHVWKHEXUQHUXQWLODÀRZWHPSHUDWXUHRI&LVUHDFKHG7KLVIXQFWLRQLVHQDEOHGZKHQ
WKHERLOHULVVZLWFKHGRQWKHJDVVXSSO\LVRSHQDQGWKHV\VWHPLVFRUUHFWO\SUHVVXULVHG
$QWLEORFNSXPSIXQFWLRQ
,IQRKHDWGHPDQGLVUHFHLYHGLQWKHKHDWLQJDQGRU'+:PRGHVIRUFRQVHFXWLYHKRXUVWKHSXPSZLOODXWRPDWLFDOO\VWDUWDQG
operate for 10 seconds.
7KUHHZD\YDOYHDQWLEORFNDJHIXQFWLRQ
,IQRKHDWGHPDQGLVUHFHLYHGIRUDSHULRGRIKRXUVWKHWKUHHZD\YDOYHSHUIRUPVDFRPSOHWHVZLWFKLQJF\FOH
+\GUDXOLFVDIHW\YDOYHKHDWLQJFLUFXLW
This device is set to 3 bar and is used for the heating circuit. Connect the safety valve to a drain trap. Do not use it to drain the
heating circuit.
+HDWLQJSXPSSUHFLUFXODWLRQ
In case of a heat demand in the heating mode, the appliance can pre-circulate the pump before the burner is ignited. This pre-
FLUFXODWLRQSKDVHODVWIURPDIHZVHFRQGVWRDIHZPLQXWHVGHSHQGLQJRQWKHRSHUDWLQJWHPSHUDWXUHDQGLQVWDOODWLRQFRQGLWLRQV
19. PUMP CAPACITY/ HEAD
A high-head
PRGXODWLQJ
pump is used (the chart in annex
"SECTION" E
VKRZVWKHPRGXODWLQJUDQJHIURPWKHPLQLPXPWRWKH
PD[LPXPYDOXHVXLWDEOHIRUXVHRQDQ\W\SHRIRQHRUWZRSLSHKHDWLQJV\VWHP7KHDXWRPDWLFDLUYDOYHLQFRUSRUDWHGLQWKHSXPS
DOORZVTXLFNYHQWLQJRIWKHKHDWLQJV\VWHP
KEY TO PUMP CHARTS -
"SECTION" E
Q
RATE OF FLOW
H
HEAD
MIN
Minimum speed of modulation
MAX
Maximum speed of modulation