4 Operating the boiler
4.1
Commissioning the boiler
1. Check the water pressure in the heating system.
If the water pressure is lower than 0.8 bar, more water
should be added. If necessary, top up the water level in the
heating system (recommended hydraulic pressure
between 1 and 2 bar).
¼
See chapter: "Filling the system", page 15
2. Open the gas valve on the boiler.
3. Turn the boiler on.
4. The boiler will begin an automatic venting-programme (which lasts
approx. 4 minutes) and will do this every time the power supply is
isolated. Both push buttons on the instrument panel light up green
during the venting cycle.
The current operating condition of the boiler is shown by the status
signal on the instrument panel. The status signal for the
B
button
can flash in a range of colours and at different frequencies. The
meaning of these signals can be found in the User instruction card
supplied with the boiler.
See also:
¼
"User instruction card", page 25
¼
"Error codes", page 18
4.2
Reading the various current values
Boiler status information can be read using a suitable controller. The
following current values can be read off the information menu
Q
:
4
State.
4
Sub-status.
4
Flow temperature (°C).
4
Return temperature (°C).
4
Calorifier temperature (°C).
4
Outside temperature (°C) (Only with an outside temperature
sensor).
4
Solar boiler temperature (°C).
4
Ionization current (µA).
4
Fan speed in rpm.
4
Water pressure (bar (MPa)).
4
Supplied relative heat output (%).
4. Operating the boiler
Baxi MainEco Combi and System 24 - 28 - 35 / 18 -24
12
02092014 - 7621607-02
Summary of Contents for MainEco Combi 24
Page 5: ...02092014 7621607 02 3 ...
Page 28: ...10 Appendix Baxi MainEco Combi and System 24 28 35 18 24 26 02092014 7621607 02 ...
Page 29: ...Baxi MainEco Combi and System 24 28 35 18 24 10 Appendix 02092014 7621607 02 27 ...
Page 30: ...10 Appendix Baxi MainEco Combi and System 24 28 35 18 24 28 02092014 7621607 02 ...