5.0 Clearances
8
© Baxi Heating UK Ltd 2013
5.1
For your Safety
1. This appliance must have been installed in accordance
with the manufacturer’s instructions and the regulations in
force.
2. Any modification that may interfere with the normal
operation of the appliance without express written
permission from the manufacturer or his agent could
invalidate the appliance warranty. In GB this could also
infringe the Gas Safety (Installation and Use) Regulations.
3. Your boiler must not be operated without the casing
correctly fitted.
4. Do not interfere with any sealed components on this
boiler.
5. Take note of any warning labels on your boiler.
6. Your boiler should have the following minimum
clearances for Safety and Maintenance
(Figs. 3 & 4):-
Top
- 175mm
Bottom
- 150mm*
Left side
- 5mm
Right Side
- 5mm
Front
- 5mm (In Operation)
- 450mm (For Servicing)
*This is MINIMUM recommended dimension. Greater
clearance will aid installation and maintenance.
7. If your boiler is installed in a compartment, do not use it
for storage purposes. Do not obstruct any purpose
provided ventilation openings.
8. Flammable materials must not be stored in close
proximity to your boiler.
9. Avoid skin contact when your boiler is in operation, as
some surfaces may get hot e.g. pipework.
10. Ensure that the flue terminal, outside the house, does
not become damaged or obstructed, particularly by foliage.
11. It is important that the condensate drain system is not
blocked, modified or damaged in any way as this would
affect the operation of your boiler. Your installer should
have insulated any exposed pipework (Fig. 5).
GB
- Heating Industry definition meaning England, Scotland,
Wales, Northern Ireland, Isle of Man and the Channel Isles
150mm* Min
5mm Min
5mm Min
5mm
450mm
For Servicing
Purposes
Fig. 3
Fig. 4
In Operation
At least
1.5°
300mm
(290mm with flap removed)
175mm Min (300mm Min if
using 80/125 flue system)
Boiler
2.5° Minimum fall
50mm per metre of pipe run
Any pipe outside MUST be
insulated. If the pipe run
inside is in an unheated area
it must also be insulated.
Example of condensate
drain system
Fig. 5
390mm
700mm