9
Fig. 6
Flue Duct Clamp
Bride de serrage du conduit des fumées
Flue Duct
C
onduit des fumées
Air Duct
C
onduit d
’
air
Seal
J
oint
Clip
C
o
ll
ier
Screws
V
is
Fig. 7
Flue Options
1. The Baxi appliance can be fi tted with fl ue systems as illustrated.
2. The standard fl ue is suitable only for horizontal applications.
3. Maximum permissible equivalent fl ue lengths are:
Concentric
3 m
Vertical
3 m
4. Any additional “in line” bends in the fl ue system must be taken into
consideration.
Their equivalent lengths are:-
Concentric Pipes:
45° bend
0.5 metres
90° bend
1.0 metres
The elbow supplied with the standard horizontal fl ue is not included in
any equivalent length calculations
5. The illustrations opposite show examples of maximum equivalent len-
gths.
6. Instructions for guidance and fi tting are included in each kit.
Options pour l’évacuation des fumées
1. L’appareil Baxi peut être équipée des options d’évacuation des fumées
illustrées ci-contre.
2. Le conduit standard ne convient que pour les applications horizonta-
les.
3. Les longueurs équivalentes maximales admises pour le conduit des
fumées sont :
Conduits concentriques
3 m
Conduits
verticaux
3
m
4. Il faut prendre en compte les coudes éventuellement montés “en ligne”
dans le système d’évacuation des fumées. Leurs longueurs équivalentes
sont :-
Conduits concentriques :
Coude de 45 °
0,5 mètre
Coude de 90 °
1,0 mètre
Le coude fourni avec le conduit des fumées horizontal standard n’est pas
pris en compte dans les calculs des longueurs équivalentes.
5. Les fi gures ci-contre donnent des exemples de longueurs équivalentes
maximales.
6. Les instructions de montage sont inclues dans chaque kit.