6.3.2
Assembly of the expansion vessel
1. Connect the hydraulic connection to the expansion vessel.
2. Screw on the bracket for the expansion vessel with the screws
supplied.
3. Hang the expansion vessel using the intended groove on the hydraulic
connection. Fix the expansion vessel in place with the connector nut.
4. Connect the flow line of the safety unit outlet to the expansion vessel
connection.
Importante
To guarantee that all connections are leak-tight, use the sealing
washers included in the kit's accessories bag.
6.4
System connection
Advertencia
Make the appliance's electrical connections in compliance with the
requirements of the prevailing standards, the information given in
the electrical diagrams delivered with the appliance, and the
recommendations in this instruction manual.
Atención
Only qualified professionals may carry out electrical connections,
always with the power off.
Earth the appliance before making any electrical connections. This
machine is only electrically safe if it is correctly connected to an efficient
earth system in compliance with current safety regulations.
Disconnect the power supply at the mains before carrying out any work on
the appliance or accessories connected to the appliance.
The unit is supplied fully pre-wired. Do not modify the connections inside
the control panel.
The mains supply is made via the connection cable pre-wired in the
appliance.
Fig.19
Assembly of the expansion vessel
1
2
4
3
1.1
3.1
4.1
4.2
BA-0000032-01
6 Installation
22
Solar hydraulic unit
7729335 - 04 - 12052021