Advertencia
If the power cable is damaged, for safety reasons this must only
be replaced by the manufacturer, by its after sales department or
by qualified personnel.
The appliance must be powered with a circuit equipped with a omnipolar
switch with a contact opening distance of 3 mm. To replace the cable, use
a cable approved in line with HAR H05 VV-F with a suitable cross-section.
Earthing must comply with the prevailing installation standards.
Precaución
Separate the sensor cables from the 230 V circuit cables. The
installation must be fitted with a main switch.
All connections are made to the terminal blocks provided for that purpose
in the system's connection box.
Importante
Failure to comply with these instructions could lead to interference
and control unit malfunctioning, damage to the electronic circuitry,
damage to the installation and even compromise the safety of
persons.
6.5
Use of high-efficiency pumps
Atención
Modifications of any kind to the heat insulation are not permitted.
The pump motor must not be covered.
In addition to the power cable, high-efficiency pumps with speed control
require a separate cable to transmit the control signal (signal cable).
1. Power supply 230 V
2. Signal cable
3. Blue = GND (earth)
4. Brown = PWM (output signal)
Fig.20
Connecting the pump wiring
2
4
3
1
L N
BA-0000035-01
6 Installation
7729335 - 04 - 12052021
Solar hydraulic unit