4.2.4
Thermodynamic water heater heating time
The graphs opposite show the heating time for the domestic hot water
tank based on the air temperature.
x Room temperature (°C)
y Heating time (hours)
1 Heating time for a DHW setpoint of 55 °C
2 Heating time for a DHW setpoint of 40 °C
Tab.13
Room temperature
(°C)
COP
Heat output (W)
7
1864
15
4.05
2157
20
4.51
2393
35
5.91
3556
(1) Value obtained with an air temperature of 7°C and a cold water temperature
of 10°C, according to LCIE Specifications No. 103-15/B:2011 based on the
NF EN 16147 standard, with a 5-m long refrigerant connection with 0 m dif
ference in height.
x Room temperature (°C)
y Heating time (hours)
1 Heating time for a DHW setpoint of 55 °C
2 Heating time for a DHW setpoint of 40 °C
Tab.14
Room temperature
(°C)
COP
Heat output (W)
7
1864
15
4.19
2157
20
4.67
2393
35
6.12
3556
(1) Value obtained with an air temperature of 7°C and a cold water temperature
of 10°C, according to LCIE Specifications No. 103-15/B:2011 based on the
NF EN 16147 standard, with a 5-m long refrigerant connection with 0 m dif
ference in height.
Fig.9
Heating time of the SPC Split 200
FS for a cold water temperature of
10 °C
MW
-1
0
0
1
6
2
6
-1
y
x
1
2
0.0
5.0
10.0
15.0
20.0
25.0
-15
-5
5
15
25
35
45
Fig.10
Heating time of the SPC Split 300
FS for a cold water temperature of
10 °C
MW
-1
0
0
1
6
8
6
-1
y
x
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
-15
-5
5
15
25
35
45
1
2
4 Description of the product
7740321 - v04 - 03122019
SPC Split
27