6 Installation
6.1
General
Caution
Installation of the heat pump must be done by a qualified
professional in accordance with prevailing local and national
regulations.
6.2
Preparation
6.2.1
Levelling the domestic hot water tank
The domestic hot water tank is levelled using three feet screwed onto the
base of the appliance.
Important
The adjustable feet are provided in the instructions bag.
1. Screw on the adjustable feet A.
2. Return the domestic hot water tank to the vertical position.
3. Adjust the height of the feet with a spanner.
Important
Adjustment range: 4 to 21 mm:
Use metal blocks under the feet of the domestic hot water tank if
necessary.
Caution
Do not place the blocks on the exterior sides of the domestic hot
water tank.
6.2.2
Installing the control panel
All the screws and dowels required for installing the control panel are
supplied.
1. Open the control panel by unclipping the cover on the wall bracket.
2. Place the box horizontally against the wall and check its position with
a spirit level.
3. Use a pencil to mark the positions for the mounting screws.
Fig.28
Levelling
MW-4000124-1
A
(x3)
Fig.29
MW-4000125-2
2
1
3
6 Installation
7740321 - v04 - 03122019
SPC Split
41