For more information, see
9.3
Displaying the measured values
The system constantly measures different data, such as the water
temperature or energy consumption. This data can be read on the control
panel.
1. Press the and keys simultaneously.
2. Scroll through the measured values with the or keys.
Tab.21
Code
Description
Factory setting / Unit
Water temperature
°C
Outside air temperature
°C
Evaporation temperature
°C
Hysteresis for starting heating.
Can be set from 3 to 20°C.
5°C
Electric power consumption
A
Differential live/neutral current
A
Total energy consumption for the thermodynamic water heater
kWh
Energy consumption of the heat pump from midnight
Wh
Energy consumption of the immersion heater from midnight
Wh
Total runtime for the thermodynamic water heater
hours
Total duration of compressor operation
hours
Total runtime for the immersion heater
hours
Operating mode:
= : thermodynamic water heater off
= : heat pump on
= : electrical back-up on
Fan speed:
: fan off
: low speed
: high speed
First error code
Second error code
Third error code
Software version
(1) Negative temperatures are displayed as follows: –10 °C is displayed as –A, –11°C is displayed as –B, etc...
9 Settings
7740321 - v04 - 03122019
SPC Split