13.3 Maintenance protocol
For more information, see
Standard inspection and maintenance operations, page 66
13.4 ErP information
Tab.35 Product fiche for heat pump water heaters
Brand name – Product name
Unit
SPC Split 200
FS
SPC Split 300
FS
Declared load profile
-
L
XL
Water heating energy efficiency class under average climate conditions
-
A
+
A
+
Water heating energy efficiency under average climate conditions
%
136.00
140.00
Annual energy consumption
kWh
754
1199
Other load profiles for which the water heater is suitable to use and the
corresponding water heating energy efficiency and annual electricity con
sumption.
-
-
-
Thermostat temperature setting
°C
55.00
54.00
Sound power level
L
WA
dB(A)
17
17
Ability to function during off-peak hours
-
No
No
-
No
No
Water heating energy efficiency, under colder - warmer climate conditions %
90.00 - 167.00
92.00 - 173.00
Annual energy consumption, under colder - warmer climate conditions
kWh
1141 - 612
1813 - 970
Sound power level
L
WA
outdoors
dB(A)
57
57
(1) Electricity
(2) If applicable
(3) If the smart control settings value is "1", the water heating energy efficiency and annual electricity and fuel consumption information only
relates to enabled smart control settings.
See
For specific precautions about assembling, installing and
maintaining: See Safety Instructions
13 Appendix
7740321 - v04 - 03122019
SPC Split