9
Installation of OpenTherm connections
To connect using the OT terminals
1. Connect the OpenTherm connectors
on the boiler to the
OT
terminals
on the gateway
Do not connect 230V to these
terminals or it will damage the
gateway
2. These will communicate with the
boiler to control the heating and
other functions
3. These connections can be made
using bell wire. There is no polarity
at the OT terminals.
1
3
2
1
4
3
1
: 24V Power supply
2
: OT controlled boiler
3
: Room Unit
1
: 24V Power supply
3
: Room Unit
4
: ON/OFF controlled boiler
OpenTherm
ON / OFF
1
OT
ON OFF
1: 24V Power supply
3: Room unit
2: OpenTherm controlled boiler