background image

Page 7

For technical questions, please call 1-888-866-5797.

Item 64416 
        

Sa

F

ety

Opera

ti

O

n

Maintenance

Setup

initial tool Set up/assembly

  read the entire iMpOrtant SaFety inFOrMatiOn section at the beginning of this 

manual including all text under subheadings therein before set up or use of this product.

note:

 For additional information regarding the parts listed in the following pages, 

refer to the Assembly Diagram near the end of this manual�

note:

 This air tool may be shipped with a protective plug covering the air inlet�  Remove this plug before set up�

air Supply

tO preVent SeriOuS inJury FrOM eXpLOSiOn: 
use only clean, dry, regulated, compressed air to power this tool.   
Do not use oxygen, carbon dioxide, combustible gases,  
or any other bottled gas as a power source for this tool.

1�  Incorporate a filter, regulator with pressure gauge, 

in-line shutoff valve, and quick coupler for best 
service, as shown on Figure A on page 8 and 
Figure B on page 9� 

 an in-line shutoff ball 

valve is an important safety device because 
it controls the air supply even if the air hose 
is ruptured.  the shutoff valve should be a 
ball valve because it can be closed quickly.

2�  Attach an air hose to the compressor's air outlet�  

Connect the air hose to the air inlet of the tool�  
Other components, such as a coupler plug 
and quick coupler, will make operation 
more efficient, but are not required�

WarninG!  tO preVent SeriOuS inJury 

FrOM acciDentaL OperatiOn: 
Do not install a female quick coupler on the tool.

  

Such a coupler contains an air valve that will 
allow the air tool to retain pressure and operate 
accidentally after the air supply is disconnected�

note: 

Air flow, and therefore tool performance, 

can be hindered by undersized air supply components�  
The air hose must be long enough to reach 
the work area with enough extra length to 
allow free movement while working�

3�  Turn the tool's throttle or switch to the off position; 

refer to Operation section for description of controls�

4�  Close the in-line shutoff valve between 

the compressor and the tool�

5�  Turn on the air compressor according to 

the manufacturer's directions and allow it 
to build up pressure until it cycles off�

6�  Adjust the air compressor's output regulator 

so that the air output is enough to properly 
power the tool, but the output will not exceed 
the tool's maximum air pressure at any time�  
Adjust the pressure gradually, while checking the 
air output gauge to set the right pressure range�

7�  Inspect the air connections for leaks�  

Repair any leaks found�

8�  If the tool will not be used at this time, turn off 

and detach the air supply, safely discharge 
any residual air pressure, and release 
the throttle and/or turn the switch to its off 
position to prevent accidental operation�

9�  Residual air pressure should not be present 

after the tool is disconnected from the air supply�  
However, it is a good safety measure to 
attempt to discharge the tool in a safe fashion 
after disconnecting to ensure that the tool 
is disconnected and not powered�

Summary of Contents for 64416

Page 1: ...equired for assembly and service may not be included Read this material before using this product Failure to do so can result in serious injury SAVE THIS MANUAL Owner s Manual Safety Instructions Save...

Page 2: ...in minor or moderate injury Addresses practices not related to personal injury iMpOrtant SaFety inStructiOnS inStructiOnS pertaininG tO a riSK OF Fire eLectric SHOcK Or inJury tO perSOnS WarninG When...

Page 3: ...an increased risk of electric shock if your body is grounded 11 explore the workpiece to avoid contact with hidden wiring Thoroughly investigate the workpiece for possible hidden wiring before perfor...

Page 4: ...ssure range 2 Never use oxygen carbon dioxide combustible gases or any bottled gas as an air source for the tool Such gases are capable of explosion and serious injury to persons SaVe tHeSe inStructiO...

Page 5: ...g flying debris generated by various operations The eye protection must be capable of stopping flying debris generated by various operations The dust mask or respirator must be capable of filtering ou...

Page 6: ...blue fingers seek medical advice as soon as possible 2 Do not smoke during use Nicotine reduces the blood supply to the hands and fingers increasing the risk of vibration related injury 3 Wear suitab...

Page 7: ...uS inJury FrOM acciDentaL OperatiOn Do not install a female quick coupler on the tool Such a coupler contains an air valve that will allow the air tool to retain pressure and operate accidentally afte...

Page 8: ...r Hose Connects air to tool B Filter Prevents dirt and condensation from damaging tool or workpiece C Regulator Adjusts air pressure to tool D Lubricator optional For air tool lubrication E Coupler an...

Page 9: ...bration reduction E Main Air Line 3 4 minimum recommended Distributes air to branch lines F Ball Valve To drain moisture from system G Branch Air Line 1 2 minimum recommended Brings air to point of us...

Page 10: ...prevent distraction and injury 2 Route the air hose along a safe route to reach the work area without creating a tripping hazard or exposing the hose to possible damage The hose must be long enough to...

Page 11: ...ander to move in the direction of rotation resuting in loss of control of the tool 6 The speed of the Sander may be varied by turning the air Regulator Value note Do not allow free no load rotating at...

Page 12: ...or housing misalignment or binding of moving parts cracked or broken parts and any other condition that may affect its safe operation 2 Daily air Supply Maintenance Every day maintain the air supply a...

Page 13: ...and wash replace the Sander s filter Severe air leakage Slight air leakage is normal especially on older tools 1 Cross threaded housing components 2 Loose housing 3 Damaged valve or housing 4 Dirty w...

Page 14: ...aSe reaD tHe FOLLOWinG careFuLLy THE MANUFACTURER AND OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER OR DISTRIBUTOR MA...

Page 15: ...Page 15 For technical questions please call 1 888 866 5797 Item 64416 SaFety OperatiOn Maintenance Setup assembly Diagram...

Page 16: ...o the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take a...

Reviews: