BayRS Version 13.10 Document Change Notice
48
300020-C Rev. 00
50-Pin to F RS-232 Synchronous Pass-Through (Order No. 7945)
Industry Interface Type: RS-232-C
Bay Networks Termination
Remote Termination
Signal
Pin # to Pin #
Signal
Send Data +
2
3
Receive Data
Receive Data +
3
2
Send Data
Request to Send +
4
8
Data Carrier Detect
Data Carrier
9
4
Request to Send
Send
10
15
Send Timing
Frame Ground
1
1
Frame Ground
Signal Ground
7
7
Signal Ground
Internal Wire Connections
Pin 4 >
5
Pin 4 >
5
Pin 10 >
11 >
12
Pin 15 >
17
Pin 13 >
38
Pin 6 >
20
Pin 14 >
39
Pin 7 >
30 >
31
15 ft
(4.57 m)
Pin 1
Pin 25
Pin 26
Pin 50
Pin 1
Pin 13
Pin 14
Pin 25
25-position D-sub receptacle with screw locks
(ground shield connected to backshell)
50-position 0.8-mm plug
(ground shield connected to internal shell)
CAB0083A