BayStream 7.3 Documentation Change Notice
115385-D Rev 01
BayStream Multiservice Software Version 7.3
117
Name:
wfFrSwDlcmiSvcStatsEnable
Object ID:
1.3.6.1.4.1.18.3.5.9.6.1.1.69
Type:
Integer
Access:
Read/Write
Default:
Disabled
Description:
Indicates whether the SVC circuits on this interface are to be included during statistical
data collection.
Name:
wfFrSwDlcmiLoopback Status
Object ID:
1.3.6.1.4.1.18.3.5.9.6.1.1.70
Type:
Integer
Access:
Read Only
Default:
Disabled
Description:
Indicates the current state of the network equipment regarding Loopback condition.
Possible states are:
•
normal (1)
•
suspected (2)
•
loopback (3)
Name:
wfFrSwDlcmiLoopbackEnable
Object ID:
1.3.6.1.4.1.18.3.5.9.6.1.1.71
Type:
Integer
Access:
Read/Write
Default:
Disabled
Description:
This attribute enables the Annex A software loopback detection feature.
High Speed Serial Interface
The following HSSI attributes are new to the wfHSSIEntry table.