Statistics Data Collection File
BayStream Statistical Data Collection software gathers, aggregates, and reports
on three types of records for ATM lines:
•
Interface card or slot (the equivalent of one OC-3 line)
•
ATM PVCs configured for a slot
•
Each virtual channel (VCL statistics) pertaining to an ATM-configured slot
VCL statistics are new for BayStream Version 7.3. To support VCL statistics
collection in Site Manager, the ATMizer VCL Bit Mask parameter has been
added.
[4:1] $ list -i wfFrSwDlcmiEntry
BYS0094A
TI list command
instances (show all instances of wfFrSwDlcmiEntry)
DLCMI MIB Entry
[4:1] $ set wfFrSwDlcmiEntry.4.wfFrSwDlcmiSvcStatsEnable 2; commit
BYS0095A
TI set command
DLCMI MIB Entry
circuit number
attribute identifier
attribute value (1=disable; 2= enable)