BayStream 7.3 Documentation Change Notice
115385-D Rev 01
BayStream Multiservice Software Version 7.3
57
Change to
Event Messages
This section includes both new and modified event messages for the frame relay
switch (FRSW), non-volatile file system (NVFS), Telnet server protocol
(TELNET), and recorded statistics (STATS) entities.
Frame Relay Switch (FRSW) Events
Entity Code/Event Code
FRSW_BILLING/146
Decimal Identifier
16794258
Severity:
Info
Message:
Invalid length of Switch Name was entered.
Meaning:
The switch name provided has more than six characters.
Action:
Enter a switch name that is six or fewer characters.
Entity Code/Event Code
FRSW/226
Decimal Identifier
16794082
Severity:
Warning
Message:
No RNNI CFG found for Line Number <line_no.>.
Meaning:
The RNNI interface configuration is incorrect.
Action:
Create wfFrSwRnniCfgEntry for the specified line number.
Entity Code/Event Code
FRSW/227
Decimal Identifier
16794083
Severity:
Warning
Message:
NNI link on slot <slot_no.> has transitioned to LIV_DOWN state.
Meaning:
The RNNI interface on the specified slot has transitioned to the liv_down state. Either the
LIVO polls are missing, or a switch-over occurred.
Action:
Check the status of the corresponding interface on the master node to see if it either
missed sending LIVO polls, or a switch_over has occurred.