background image

 

ii

893-00940-A

 

© 1996 by Bay Networks, Inc. All rights reserved.

 

Trademarks

 

Bay Networks, Bay Networks Press, and Centillion 100 are trademarks of Bay Networks, Inc. 

Other brand and product names are registered trademarks or trademarks of their respective holders.

 

Electromagnetic Emissions

 

Electromagnetic emissions and declaration of conformity information is provided in the 

 

Installation and 

Reference for the Centillion 100 Chassis

 

.

 

Related Publication

 

For more information about the installation and use of the Centillion 100

 

 

 

 

Chassis, refer to the following 

publication:

 

Installation and Reference for the Centillion 100 Chassis

 

(Bay Networks

 

 

 part number 893-894-A)

Describes the Centillion 100 Chassis installation procedures.

 

Ordering Bay Networks Publications

 

To purchase additional copies of this document or other Bay Networks publications, order by part number 
from Bay Networks Press

 

 

 at the following numbers. 

Phone—U.S./Canada: 1-888-422-9773 (1-888-4BAYPRESS)

Phone—International: 1-510-490-4752

FAX—U.S./Canada/International: 1-510-498-2609

You can also use these numbers to request a free Bay Networks Press catalog.

 

Bay Networks Customer Support

 

Bay Networks provides live telephone technical support to our distributors, resellers, and service-contracted 
customers from U.S. and international support centers. If you have purchased your Bay Networks product 
from a distributor or authorized reseller, contact the technical support staff of that distributor or reseller for 
assistance with installation, configuration, troubleshooting, or integration issues.

For additional information or advice, contact the Bay Networks Technical Response Center in your area:

United States

1-800-2LANWAN

Valbonne, France

(33) 92-966-968

Sydney, Australia

(61) 2-903-5800

Tokyo, Japan

(81) 3-3288-0331

 

C100PS.Bk  Page ii  Friday, May 9, 1997  1:54 PM

Summary of Contents for Centillion 100

Page 1: ...Part No 893 00940 A July 1996 Installing the Power Supply for the Centillion 100 Chassis C100PS Bk Page i Friday May 9 1997 1 54 PM ...

Page 2: ...r other Bay Networks publications order by part number from Bay Networks Press at the following numbers Phone U S Canada 1 888 422 9773 1 888 4BAYPRESS Phone International 1 510 490 4752 FAX U S Canada International 1 510 498 2609 You can also use these numbers to request a free Bay Networks Press catalog Bay Networks Customer Support Bay Networks provides live telephone technical support to our d...

Page 3: ...snetz in Ihrem Land geeignet ist darf es nicht verwendet werden Besorgen Sie sich ein Kabel das die Vorschriften der Zulassungsbehörden in Ihrem Land erfüllt Die technische Dokumentation dieses Produkts enthält ausführliche Installationsanweisungen die nur von qualifiziertem Kundendienstpersonal ausgeführt werden dürfen Attention Lisez ceci immédiatement Examinez ce cordon d alimentation pour déte...

Page 4: ...sere seguite dal personale di servizio consultare questa documentazione tecnica del prodotto Advertencia Sírvase leer inmediatamente Inspeccione este cable de alimentación eléctrica y determine si viene con el enchufe apropiado y está debidamente certificado para el uso con su sistema eléctrico Si no cumple con los reglamentos del sistema eléctrico de su país despójese de este cable de alimentació...

Page 5: ... flat tip screwdriver to loosen the two screws then remove the filler panel from the chassis 2 Align the new power supply with the slot guides and slide the power supply into the chassis CAUTION Only qualified technicians should install this equipment 7265 7266 C100PS Bk Page 3 Friday May 9 1997 1 54 PM ...

Page 6: ... and 4 inch pounds of torque Do not overtighten 4 Connect the power cord to the power supply and then to the wall See power cord caution on page 1 5 Turn on the power Verify that the upper green LED lights For detailed instructions refer to Installation and Reference for the Centillion 100 Chassis 7267 7268 LEDs Power switch C100PS Bk Page 4 Friday May 9 1997 1 54 PM ...

Page 7: ...1 Turn off the power to the faulty power supply and unplug the cord 2 Use the flat tip screwdriver to loosen the two screws then remove the power supply from the chassis CAUTION Only qualified technicians should replace this equipment 7269 Power switch 7270 C100PS Bk Page 5 Friday May 9 1997 1 54 PM ...

Page 8: ...3 Align the new power supply with the slot guides and slide it into the chassis 4 Push down on the power supply handle to align the screws and tighten the screws to between 2 and 4 inch pounds of torque Do not overtighten 7271 7272 C100PS Bk Page 6 Friday May 9 1997 1 54 PM ...

Page 9: ...ply and then to the wall See power cord caution on page 1 6 Turn on the power Verify that the upper green LED lights For detailed instructions refer to Installation and Reference for the Centillion 100 Chassis 7273 7273 1 Power switch LEDs C100PS Bk Page 7 Friday May 9 1997 1 54 PM ...

Page 10: ... Input voltage Input current rating Fuses 47 to 440 Hz 250 VA 90 to 132 V or 180 to 264 V 5 2 5 A Internal not accessible to user Thermal rating One power supply Multiple power supplies 850 BTU hr maximum 900 BTU hr maximum Physical Dimensions Handle projection Weight 2 4 in H x 6 5 in W x 12 in D 6 1 cm H x 16 5 cm W x 30 5 cm D 1 in 2 54 cm 1 6 lb 0 725 kg C100PS Bk Page 8 Friday May 9 1997 1 54...