Installing the ATMSpeed/155 Modules
893-01047-B
2-17
Verifying the Installation
When the ATMSpeed/155 module is installed and the cables are connected to the
ports, the module is ready for operation. All connected ports are enabled, unless
they have been disabled by SpeedView. Enabling and disabling ATMSpeed/155
module ports is described in Using SpeedView 3.0 for Windows.
You can verify the installation of an ATMSpeed/155 module by observing the
LEDs on the module while the module is operating and at system startup. This
section describes the ATMSpeed/155 module LEDs and the LED sequence at
startup.
Interpreting ATMSpeed/155 Module LEDs
The ATMSpeed/155 MDA and MDA MCP modules have six LEDs for each ATM
port, as shown in
Figure 2-26
.
Table 2-1
lists the meaning of each LED.
Figure 2-26.
ATMSpeed/155 MDA and MDA MCP Module LEDs for ATM
Ports
Table 2-1.
ATMSpeed/155 MDA and MDA MCP Module LED Definitions
for ATM Ports
LED Name
Meaning
En
Remains on while port is enabled from network management.
RX
Turns on as calls are received on the port.
TX
Turns on as cells are transmitted on the port.
FERF
Turns on for far end receiver fault (FERF), also known as remote
defect indication (RDI).
LOF
Turns on to indicate loss of frame.
LOS
Turns on to indicate loss of signal.
En/FERF
RX/LOF
TX/LOS
1
2
3
4
7883PEA