Safety instructions and important notes

 

Only use the breast pump in accordance with the instructions 
included in this user's  manual . Not adhering to these instructions 
may result in incorrect operation of the breast pump or may damage 
it . Keep this manual for future use .

 

This breast pump may be handled by children 8 years of age and 
older or by persons with physical or mental impairments or by 
inexperienced persons, if they are properly supervised or have been 
informed how to handle it in a  safe manner and understand the 
potential dangers . Children must not play with the breast pump and 
its accessories . 

 

Only use the breast pump with the original power adaptor and 
accessories . 

 

Before connecting the power adaptor to a power socket, make sure 
the voltage stated on its rating label corresponds to the voltage in the 
power socket .

 

For hygiene reasons, the breast pump is intended for repeated use 
by only a single user . 

 

Do not start the breast pump if there is water inside the silicon tubing 

A

qk

 .

 

Do not use the breast pump outdoors, do not expose it to direct 
sunlight or put it down on an electric or gas stove .

 

The breast pump is not intended to be used in the shower or bath . 

 

Do not use the breast pump in the event of excessive fatigue or 
sleepiness or while driving a motor vehicle .

 

We do not recommend using the breast pump during pregnancy as 
this could induce childbirth . 

 

Do not attempt to take the breast pump off the breast while milk is 
being expressed . First, turn off the breast pump and only thereafter 
release the breast from the silicon breast pad 

A

2

 . 

Summary of Contents for BBP 1010

Page 1: ...ower source 8 Using the breast pump 8 Tips and advice for using the breast pump 9 Storing and heating up breast milk 9 Troubleshooting 10 Cleaning and sterilization 11 Storage 12 Technical specificati...

Page 2: ...the second phase where a deeper slower suction action of the infant is emulated In this phase breast milk is expressed from the breast nipple and pumped into a bottle The stimulation and expression in...

Page 3: ...aptor and accessories Before connecting the power adaptor to a power socket make sure the voltage stated on its rating label corresponds to the voltage in the power socket For hygiene reasons the brea...

Page 4: ...rge the pump unit or power adaptor in water or any other liquids or sterilize these parts because they do not come into contact with the breast milk or the breast Cleaning may be performed by children...

Page 5: ...o a narrow neck baby bottle 0 Bottle seal cap qa Silicon nipple qs Wide neck baby bottle volume 120 ml qd Bottle stand qf Bladder cap qg Inner cap stopper qh Silicon bladder qj Pump unit qk Silicon tu...

Page 6: ...display shows EXPRESSION 5 SUCTION scale shows the suction intensity setting 6 Power adaptor socket 7 SPEED scale shows the speed of stimulation expression 8 Increase suction intensity button 9 Decrea...

Page 7: ...y upwards so that the lip located on the nozzle slides in first Then carefully push the plastic brace A3 on to the bottle connector A4 so that these parts are connected Into the top part of the bottle...

Page 8: ...er level B2 The approximate operating time of the breast pump when new batteries are used is 60 minutes After approximately 60 minutes of operation suction intensity will decline even when the battery...

Page 9: ...fault settings will be renewed as when the breast pump was started for the first time 6 Take the breast out of the silicon pad A2 always only after turning off the pump unit Aqj Place the bottle Aqs w...

Page 10: ...to the respective bottle When necessary you can use a different baby bottle with a nipple Before feeding always first shake the bottle and check the temperature of the milk Dispose of any unused milk...

Page 11: ...r cap Aqf and the tubing Aqk with the connected tubing connectors Aql using a lightly dampened cloth Then dry both parts using a clean wiping cloth These parts do not come into contact with breast mil...

Page 12: ...ensity Max 0 016 MPa stimulation mode Max 0 034 MPa expression mode Stimulation expression speed 100 cycles minute stimulation mode 26 to 60 cycles minute expression mode Automatic shut off timer 30 m...

Page 13: ...more details In accordance with national regulations penalties may be imposed for the incorrect disposal of this type of waste For business entities in European Union states If you want to dispose of...

Reviews: