245 Bowrider • Owner’s Manual
Supplement
Chapter 5: Plumbing
29
Autofloat Switch
•
The autofloat switch turns the bilge pump On when water rises above a preset level.
•
Test the autofloat switch often.
Autofloat switch testing:
1. Lift the float switch test button to
turn On the bilge pump.
•
If the pump does not turn On, check
the fuse on the fuse block.
•
If the fuse is good, but the switch
still does not work, it may mean the
switch is bad, or the battery is dead.
2. After testing, push the test button
all the way down to return the float
switch to auto mode.
PUSH SWITCH DOWN
LIFT SWITCH UP
(BILGE PUMP SHOULD TURN ON)
(BILGE PUMP SHOULD TURN OFF)
AUTOFLOAT SWITCH
TEST BUTTON
TESTING
When the test is completed on the float switch, you MUST push the test button ALL THE WAY
DOWN to return the switch to auto mode!
CAUTI ON
!
Summary of Contents for 245 Bowrider
Page 1: ......
Page 2: ......
Page 17: ...245 Bowrider Owner s Manual Supplement 11 Chapter 2 Locations Exterior Views Hull Views...
Page 18: ...Chapter 2 Locations 245 Bowrider Owner s Manual Supplement 12 Deck Views...
Page 56: ...Owner s Notes...
Page 57: ...Owner s Notes...
Page 58: ...Owner s Notes...
Page 59: ......
Page 60: ...Part Number 1894298 Bayliner P O Box 9029 Everett WA 98206 360 435 5571...