Freshwater System Winterization
1. Turn On the freshwater pump switch.
2. Open all of the faucets and showers and let the freshwater system drain completely.
3. Turn Off the freshwater pump switch.
All of the remaining water must be removed from the water lines. There are two ways to remove the remaining water
from the lines:
•
Compressed Air
•
Gravity Draining
Compressed Air
You must have an air compressor with an air hose and
an air nozzle.
1. Remove the water line from the outlet side of the
freshwater pump (opposite side from filter).
2. Open the faucet that is furthest away from the fresh-
water pump.
3. Place the air nozzle against the end of the just
removed water line and blow air through the system.
4. When water stops coming out of the faucet, stop the
air and Close the faucet.
5. One at a time, repeat this process on all faucets and
showers.
Gravity Draining
1. Open all faucets and showers.
2. Remove the drain plug from the tee fitting on the
freshwater tank.
3. When the water has stopped draining from the
freshwater tank and the water lines, replace the
drain plug.
FRESHWATER SYSTEM DAMAGE HAZARD!
•
A faucet MUST be Open when compressed air is blown through the freshwater system.
•
NEVER blow compressed air through the water system when ALL of the faucets are Closed.
CAUTI ON
!
TYPICAL VIEW
NOTE: LOCATION OF TEE FITTING
& DRAIN PLUG MAY VARY
FRESHWATER TANK
FILTER
FRESHWATER
OUTLET SIDE
WATER LINE
INLET SIDE
WATER LINE
DRAIN PLUG
TEE FITTING
PUMP
Summary of Contents for 245 Bowrider
Page 1: ......
Page 2: ......
Page 17: ...245 Bowrider Owner s Manual Supplement 11 Chapter 2 Locations Exterior Views Hull Views...
Page 18: ...Chapter 2 Locations 245 Bowrider Owner s Manual Supplement 12 Deck Views...
Page 56: ...Owner s Notes...
Page 57: ...Owner s Notes...
Page 58: ...Owner s Notes...
Page 59: ......
Page 60: ...Part Number 1894298 Bayliner P O Box 9029 Everett WA 98206 360 435 5571...