11
Operation
pH control operation modes
Auto
The Automatic
SALT
automatically regulates the pH value to the desired pH value in the pool.
Off
The automatic control of the pH value is switched off.
pH timelimited dosing / fill or rinse pump hoses / pause
Fill pump hoses
If the pH dosing hose is empty (e.g. before a canister change), you can start the pH pump manually here to fill the hose.
Stop the process as soon as the dosing hose is completely filled (up to the injection piece).
Time limited pH dosing
With this timer mode, the pHMinus dosing is switched on for a selectable period of time.
You can choose whether the dosing should stop when the selected setpoint is reached or only after the selected time has
elapsed.
You can also stop the dosing manually at any time.
Pause pH dosing
This mode allows to pause automatic control for a selectable period of time. After the pause has elapsed, automatic control
starts again automatically.
This mode can i.e. be used when adding water care products manually.
Salt electrolysis operating mode
Auto
The Automatic
SALT
automatically regulates the chlorine production depending on the desired redox value in the pool.
Auto plus+
The Automatic
SALT
automatically regulates the chlorine production depending on the desired redox value in the pool.
plus+:
An additional chlorine production is triggered that in an adjustable way may overshot the desired redox value in the pool.
ATTENTION
Since the use of this function allows higher redox values and therefore higher chlorine levels in the pool water a careful
configuration of this function is mandatory. Please check the level of chlorine in your pool water manually from time
to time and adjust the settings, if necessary.
The pool may only be opened for bathing when it has been ensured that the chlorine level is on a normal level.
Constant Production
In this operating mode, chlorine is produced at an adjustable production rate as long as the filter pump is switched on.
In case the pool is equipped with a pool cover the production rate may be lowered in case of closed cover to meet the
lower demand for disinfection.
Off
The automatic disinfection control and the chlorine production are switched off.
Salt electrolysis BOOST / timelimited production / pause
Boost Mode
If as much chlorine as possible has to be produced in as short a time as possible (e.g. for high chlorination), the boost
mode can be activated.
In this mode, chlorine production is switched on at full power for 24, 48 or 72 hours. If the filter pump is switched off in the
meantime and chlorine production is therefore not possible, the time stops and only starts again when the filter pump is
switched on.
After the boost time has elapsed, the Automatic
SALT
continues in the mode in which it was before starting.
ATTENTION
As the boost chlorine production does not stop when the desired redox value is reached in the pool water, an increase
in the chlorine value above the desired value is to be expected. Before activating the Boost mode, make absolutely sure
that nobody can be in the pool water both during and after the Boost chlorination. The pool may only be opened for
bathing again when it has been confirmed by measurement that the chlorine level has dropped to a normal level.
Time limited constant production
In „Activate time limited constant production“ you can switch on the chlorine production for a selectable period of time.
You can choose whether production should stop when the desired value is reached or only after the selected time has
elapsed. You can also stop production manually at any time.
Pause salt electrolysis
In the „Pause salt electrolysis“, you can stop the automatic control for disinfection for a selectable period of time. After the
pause has elapsed, the previously set automatic control starts again automatically. This mode can be advantageous, for
example, when adding water care products manually.
Safe Mode
In the „Salt electrolysing settings“ you can set whether the Automatic
SALT
stops or continues with reduced output in the
event of discrepancies in the disinfection control (e.g. desired redox value is not reached).
34