background image

2  Content of the packaging

 

 

 

4

 

Failure  to  follow  the  safety  instructions  may  result  in  danger  to  persons,  the  environment  and  the  device  itself.  Failure  to  observe  the  safety 
instructions will also lead to the forfeiture of claims for damages and loss of warranty. 
The Salt Relax POWER is intended exclusively for use in private swimming pools. 

 

DANGER! 
Danger resulting from inadequate  qualification of personnel/service technicians/installation technicians. Possible consequences are 
serious or even fatal injury and severe damage to material assets. The following conditions therefore apply: 

 

The operator of the plant must ensure that personnel are adequately qualified. 

 

All tasks must be performed exclusively by correspondingly trained personnel. 

 

The system must be protected against access by persons who are not adequately qualified, e.g. by means of access codes and 
passwords. 

 

IMPORTANT! 
The operator of the plant must ensure compliance with the relevant accident prevention regulations, other legal provisions and the 
generally accepted rules of safety engineering! 

 

2

 

Content of the packaging 

 

1   Salt Relax POWER 
2   Temperature sensor 
3   Cable grommets 
4   Installation material 
5   Reducer 75-50 mm 
6   Chlorine production cell  

  (cell and housing) 

7   Salt Quicktest  
8   Holder for temperature sensor 
9   Holder for paddle switch and  

  pH/redox electrodes (optional) 

10 Plugs 
11 Paddle switch 

3

 

Installation 

 

 

NOTE! 
Ensure  that  all  components  of  the  pool  system  which  may  come  into  contact  with  the  pool  water  are  resistant  to  salt  water.  
In particular, make sure that the filtration pump is resistant to salt water.  
Note  that  even  water  with  a  low  salt  content  can  be  corrosive,  and  take  this  into  account  when  selecting  components  for  use 
(e.g. steel ladders etc.).

 

 

 

Necessary qualification: 
The Salt Relax POWER must be installed by a specialist with both in-depth knowledge of swimming pool construction and in-depth 
knowledge of the installation of electrical and electronic devices! 

 

 

Danger caused by electrical current  
The Salt Relax POWER is live as soon as voltage is applied to the power input. The chlorine production cell or additional functions 
may be switched on or switched over. Contact with live components can lead to an electric shock. 
This may result in serious or even fatal injury and damage to material assets, and the following therefore apply: 

 

All such tasks must be carried out exclusively by adequately trained and experienced personnel! 

 

The device must always be de-energised before performing installation and maintenance work on it! 

 

Secure the device against being switched on while work is being performed on it!  

 

Additional modules must be installed/removed in de-energised state! 

 

Cables must also be connected in de-energised state! 

 

A safety feature which is independent of the device should always be present! 

 

Where necessary, password protection for the main menu must be activated! 

 

The relevant country-specific safety regulations must be complied with! 

 

All safety features and protective devices must be refitted or rendered functional again immediately after completing work! 

 

Failure to follow the safety instructions can cause the device to malfunction, may lead to the risk of fatal injury and renders the 
warranty invalid! 
 

Summary of Contents for NATURALLY SALT Salt Relax POWER

Page 1: ...Salt Relax POWER Version 2 9 EN Operating and installation manual...

Page 2: ......

Page 3: ...2 1 point pH calibration 31 6 Redox option 32 6 1 Scope of delivery redox option 32 6 2 Installing the Redox module 32 6 3 Installing the redox electrode 32 6 4 Redox setpoint 32 6 4 1 Determining the...

Page 4: ...ater In particular make sure that the filtration pump is resistant to salt water Note that even water with a low salt content can be corrosive and take this into account when selecting components for...

Page 5: ...ing by holding it up against the mounting location and marking the position of the drill holes on the wall 3 2 Electrical connection The Salt Relax POWER has been designed and constructed according to...

Page 6: ...evice is connected to a water protected mains socket with a 30 mA residual current circuit breaker See also the information in the chapters Filtration Configuration and Connecting terminals 3 3 Connec...

Page 7: ...on It is imperative to note that the chlorine production cell must always be the last element installed on the return line to the pool see sketch above To enable use of the integrated gas flow sensor...

Page 8: ...ecommends the installation of a sacrificial electrode in the pumping system of the pool Ask your specialist swimming pool dealer for details NOTE When selecting components e g steel ladders etc always...

Page 9: ...m3 Depth average depth of the water 3 8 4 Calculating the amount of salt to add The amount of salt to be added to a freshly filled pool salt free water is calculated with the following formula Desired...

Page 10: ...chlorine requirement If Salt Relax Pro is controlled via the external timer please ensure that the timer runs continuously for 24 hours Note If your pool needs a chlorine shock we recommend that you a...

Page 11: ...trol see below Automatic mode time controlled In this mode filtration can be activated via timers allowing you to enter starting and stopping times The timers run on a daily schedule Setting the daily...

Page 12: ...hen using a circulating pump with variable speed control Press the or keys to access and also change the setting Use or to switch between 1 2 and 3 Confirm your entry with The speed of the pump is set...

Page 13: ...vailable in all operating modes This menu is used to facilitate backwashing of the sand filter As soon as the menu is activated in one of the filtration modes Manual Automatic Heating Smart Intelligen...

Page 14: ...sing a suitable LED light control Next colour Confirm by pressing to manually activate the next colour on the connected LED control Switching interval Select the interval here in seconds at which the...

Page 15: ...ress to enter the minutes of the starting time and set using Confirm your entry with or reject it with The timer can also be set to switch at certain intervals daily every 2 days every 3 days every 4...

Page 16: ...er information 4 3 5 Temperature calibration In this menu the temperature sensor can be calibrated with the displayed temperature value If you control your pool heating with the Salt Relax POWER this...

Page 17: ...hether you wish to reduce the production capacity with the pool cover closed The precondition for use of this function is a closing signal when the cover is closed It is connected as described in the...

Page 18: ...confirm with Time Press or to activate entry of the time Use and to set the hour opens the input window for the minutes which you can set using and opens the input window for seconds which you can set...

Page 19: ...you can enter the code word for the selected network System settings The configuration settings are entered automatically by the system Please consult an IT expert if you are shown an error message S...

Page 20: ...er a 5 key password Enter a key combination of your choice You will be asked to enter this password each time you want to access the menu level from the main screen Remember your password To deactivat...

Page 21: ...function Electr circuitry ph PH Dosing pump pH Minus dosing pump pH Plus 230V 110V 50Hz Aux1 AUX1 Dosing pump pH Plus for pH Minus AND pH Plus dosing 230V 110V 50Hz Aux2 AUX2 Additional dosing pump f...

Page 22: ...nstalled The relay selected under Redox default Aux2 switches the additional dosing pump for disinfection if 0 is selected in parameter 4 Electrolysis mode in the Service Settings menu In this case th...

Page 23: ...olled functions e g Lighting are not switched off 0 1 2 1 Defines the reaction of the chlorine production cell and an additionally connected dosing pump for disinfection when the redox option is used...

Page 24: ...llowing can be checked should the system fail to reach the setpoint within the set time Redox electrode Setting for output of chlorine production cell Leakage in the dosing line of the additional disi...

Page 25: ...al is not envisaged for stopping the pump STOP signal Slow The circulating pump is switched to the status Slow when the heating is connected Medium The circulating pump is switched to the status Mediu...

Page 26: ...our pool Defines the maximum switch on time of the pH pump after which the pH alarm AL3 is activated This alarm indicates that although the dosing pump pH was active it was not possible to reach the p...

Page 27: ...ue 3 default setting Never set values greater than 3 in this menu If necessary change the setting with and confirm with 4 5 6 Reset settings In Reset settings all settings made can be reset to the as...

Page 28: ...he chapter Installing the pH and redox pH module Please note that installation must be performed by a specialist service technician installation engineer 5 3 Installing the pH electrode Install the pH...

Page 29: ...ect the pH option and display the associated menus at the corresponding points 5 5 Settings on the device 5 5 1 Set point pH Setpoint for unidirectional pH regulation Entry of the setpoint for unidire...

Page 30: ...7 and pH 10 in order to calculate the exact electrode slope For regular recalibration at least once a month a 1 point calibration will usually be enough If a photometer is available recalibration shou...

Page 31: ...th 1 point calibration To set select Offset 1pt with and confirm with Current measurement Shows the value measured with the current setting Target measurement Allows you to enter the actual pH value E...

Page 32: ...lectrode to the socket provided on the Salt Relax POWER 6 4 Redox setpoint For redox regulation it is not the calibration of the electrodes which plays a major role but the correct definition of the r...

Page 33: ...and confirm with Proceed as described in the previous chapter to determine the setpoint 6 4 3 1 point redox calibration 1 point calibration is carried out with the 465 mV buffer solution provided Alte...

Page 34: ...is not too long but is also not under tension Carefully feed the cable through the cable opening of the module and connect the individual cables as described to the screw terminals provided Make absol...

Page 35: ...switched on or switched over Contact with live components can lead to an electric shock This may result in serious or even fatal injury and damage to material assets and the following therefore apply...

Page 36: ...o upper clips upwards and remove them Carefully pull the housing front cover forwards until it is about 15 cm from the device Carefully pull the connecting cable between main board and display out of...

Page 37: ...e grommet Unscrew the nut of the cable gland until it is positioned on the very end of the thread Alternatively you can remove it completely Remove the plug leaving the seal in the screw fitting Feed...

Page 38: ...elf when working on the opened device Avoid touching the electronic components unnecessarily NOTE Observe the permissible maximum currents for the relays for switch outputs 1 to 3 in total not more th...

Page 39: ...he chlorine production cell is set too high Reduce the production intensity If the redox option is used redox setpoint faulty Check the redox setpoint and the correlation between redox setpoint and th...

Page 40: ...aution Leaking pH Minus pH Plus can cause chemical burns Wear gloves and safety goggles Dosing rate of the pH dosing pump is too low Increase the dosing rate by opening the red regulator of the dosing...

Page 41: ...ction cell However please note that a setting of 200 minutes or less will greatly reduce the typical life of the chlorine production cell and void the warranty If on the other hand you find that your...

Page 42: ...n over the winter activate the Antifreeze function However this may not prevent the water from freezing at exceptionally low temperatures If necessary remove the suction line from the canister and rin...

Page 43: ...e measurement Measurement via LM35 sensor stainless steel Measuring range 0 100 OC Resolution 1 OC Calibration 1 point calibration Measurement of the pH value optional Measurement via combination elec...

Page 44: ...ct model Salt Relax POWER Brand BAYROL Series no See type plate EC directives EC Low Voltage Directive 2006 95 EC EC EMC Directive 2004 108 EC Harmonizing standards used UNE EN 60335 1 2002 A1 2004 A1...

Reviews: