3 Installation
7
3.5
Installation diagram
The illustration shows connection of the Salt Relax POWER via the filter control.
The holder for electrodes and temperature sensor can also be attached directly inside the chlorine production cell with adhesive.
NOTE
We recommend that the cell is always installed in the bypass. Installation in this way is mandatory if the flow rate exceeds 15 m
3
/hour,
in order to avoid load losses. Installation in the bypass makes it much easier to carry out maintenance on the chlorine production cell
and the optionally installed sensors.
If you install the cell in the bypass, you should fit a non-return valve in the bypass line after the cell in place of a manual valve, in order
to rule out the danger of accidental actuation.
It is imperative to note that the chlorine production cell must always be the last element installed on the return line to the pool (see sketch above).
To enable use of the integrated gas flow sensor, the cell must be positioned vertically. The sensor will only function correctly if this is the case. If
installation in vertical position is not possible, the paddle flow switch supplied with the device must be used!
Please note that the water flows through the chlorine production cell as shown in the diagram and not in the reverse direction.
The chlorine production cell itself is attached inside the bypass piping with adhesive. Depending on the diameter of the pipe, it may be necessary to
use the reducer supplied.
NOTE
When inserting the cell into the cell holder, make sure that the cell blades are positioned in the direction of flow of the water. This
ensures that the blades offer the lowest possible resistance to the water flowing through the cell.