11

IV 5 – Installing the module – East West II

 

 

 

Position the module on the base feet before placing 
it on the module support set. Install the modules of 
one axis of a double row first. 

 

Place ballast in accordance with the ballast 
planning into the base troughs after installing the 
modules.

 

 
 
 
 
 

   

 

After fixing the modules place the support brace on 
the module support set and fix the support brace to 
the module support set. Support brace joint 
overlapping above the module support brace. 
 
Place ballast and install the modules on the other 
side of the double row on the module support set. 
 

 

-  Wire adjacent modules when installing them 

Install the string cable first

 

 

 

IV 6 – Fastening the module to the system  
edge / expansion joint 

 

Place the drilling screw from the flat roof end clamp 
centred over the screw channel of the base foot or 
module support and screw in. 
 

 

Tightening torque max. 6 Nm. 
The screw must not be overtightened! 
Approval from manufacturer required for clamping 
in the corner section of the long frame side. 

 

 

IV 7 – Installation / ballast without  
connection rail 

   

The amount of required ballast at the system edge 
increases if not using a connection rail. No load 
redistribution is possible. 
The adjacent modules must each be secured with 
the flat roof end clamp in the corner of the long 
frame side instead of with the flat roof mid clamp. 
 

 

Tightening torque max. 6 Nm. 
The screw must not be overtightened! 

 
 
 
 

 

Summary of Contents for closed II

Page 1: ...I Installation manual novotegra for flat roofs closed II East West II...

Page 2: ...uired for installation 4 4 2 Installation system components installation variants 5 4 3 Installation system components optional 6 5 INSTALLING THE SUBSTRUCTURE 7 5 1 Installing the base rails and supp...

Page 3: ...hat the safety information is not observed Warning symbol with signal word Hazard class as per ANSI Z 535 DANGER indicates an immediate hazard Failure to prevent this could result in death or severe i...

Page 4: ...e installation system in accordance with this installation manual is 0 to 5 degrees The given torque values must be observed and tested on a random basis on site Information on structural analysis The...

Page 5: ...may lead to different results Protection against system sliding is verified based on a coefficient of friction of 0 5 This value must be checked by the installation company prior to installation If th...

Page 6: ...ening Flat roof mid clamp Material Aluminium and V2A Tool Socket bit AF 8 mm Support and module fastening Flat roof end clamp Material Aluminium and V2A Tool Socket bit AF 8 mm Support and module fast...

Page 7: ...ce replace of base foot and module supports set in the base trough 150 30 Correct installation 4 2 Installation system components installation variants Image Tool Component Product group Module suppor...

Page 8: ...Plastic Optional item Top cover base trough 150 30 3 00m Material Aluminium Optional item Self locking cable tie Optional item Cable clip d 10 mm Optional item Grounding connector set AF 18 Material V...

Page 9: ...s tightly together push the connectors under the ridge on the base troughs and screw together with two screws on each side Maximum uninterrupted rail length approx 17 m 10 rows with approx 1 70 m gap...

Page 10: ...fter approx 17 m 10 modules next to each other After approx 34 m 20 modules the system must be properly separated The distance between the adjacent base troughs must be 50 mm 5 2 Module installation l...

Page 11: ...f required The connection rail can be used to install the string cable or to insert the required ballast IV 7 applies if installing without connection rail Further rails can be used to redistribute lo...

Page 12: ...Screw the expansion joints to the base troughs On the moving side the two screws must be screwed into the base trough so that they are centred in the slots Installation expansion joint not below a mo...

Page 13: ...es when installing them Install the string cable first IV 6 Fastening the module to the system edge expansion joint Place the drilling screw from the flat roof end clamp centred over the screw channel...

Page 14: ...IV 8 Ballast troughs Using ballast troughs allows small or large size ballst to be securely inserted if required The ballast troughs must be mounted on the side of the base troughs 10kg 35kg 10kg 35k...

Page 15: ...used in the calculation for verification of the anti slide protection for PV systems on flat roofs Coefficients of friction calculated on site can be taken into account and must be provided to BayWa...

Page 16: ...en D 90419 N rnberg Phone 49 7071 98987 300 Phone 49 89 386670 0 Phone 49 911 216646 0 Fax 49 7071 98987 139 Fax 49 89 386670 10 Fax 49 911 216646 10 tue solarenergysystems baywa re com mue solarenerg...

Reviews: