Systems Insight Display
LED and color
Health
LED
System
power LED
Status
Processor (amber)
Red
Amber
One or more of the following
conditions may exist:
• Processor in socket X has failed.
• Processor X is not installed in the
socket.
• Processor X is unsupported.
• ROM detects a failed processor
during POST.
Processor (amber)
Amber
Green
Processor in socket X is in a pre-
failure condition.
DIMM (amber)
Red
Green
One or more DIMMs have failed.
DIMM (amber)
Amber
Green
DIMM in slot X is in a pre-failure
condition.
Over temp (amber)
Amber
Green
The Health Driver has detected a
cautionary temperature level.
Over temp (amber)
Red
Amber
The server has detected a hardware
critical temperature level.
PCI riser (amber)
Red
Green
The PCI riser cage is not seated
properly.
Fan (amber)
Amber
Green
One fan has failed or has been
removed.
Fan (amber)
Red
Green
Two or more fans have failed or been
removed.
Power supply (amber)
Red
Amber
One or more of the following
conditions may exist:
• Only one power supply is installed
and that power supply is in
standby.
• Power supply fault
• System board fault
Power supply (amber)
Amber
Green
One or more of the following
conditions may exist:
• Redundant power supply is
installed and only one power
supply is functional.
• AC power cord is not plugged into
redundant power supply.
• Redundant power supply fault
• Power supply mismatch at POST
or power supply mismatch through
hot-plug addition
Table Continued