7.
.
8.
Install the server in the rack.
9.
Connect each power cord to the server.
10.
Connect each power cord to the power source.
Use the BIOS/Platform Configuration (RBSU) in the UEFI System Utilities to configure the memory mode.
For more information about LEDs and troubleshooting failed DIMMs, see "
."
Controller options
The server supports the following storage controllers:
• Embedded controllers
Enabled through System Utilities and configured through HPE Smart Storage Administrator (Intelligent
Provisioning)
• Type-a controllers
Type-a controllers install in the type-a smart array connector.
• Type-p controllers
Type-p controllers install in a PCIe expansion slot
Installing a storage controller
Prerequisites
Before installing this option, be sure that you have the following:
The components included with the hardware option kit
Procedure
.
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
62
Controller options