Error message
Description
Heating Failed on Left Hotend
A heater error on one of the Hotends or HotBed can
occur when the printer is trying to heat up but the
sensor does not report an increase in temperature or
it is not fast enough.The display will show with which
print core a problem has been detected.
Heating Failed on Right Hotend
Heating Failed on HotBed
Thermal runaway on Left Hotend
A heater error on one of the Hotends or HotBed can
occur when the printer reaches the target tempe-
rature but afterwards it detects a decrease of the
temperature. The display will show with which print
core a problem has been detected.
Thermal runaway on Right Hotend
Thermal runaway on HotBed
Max Temperature triggered on Left Hotend
This error occurs when one of the Hotends or HotBed
is reading a temperature that is too low. The display
will show with which print core a problem has been
detected.
Max Temperature triggered on Right Hotend
Max Temperature triggered on HotBed