TEST PREPARATION
Before you test a battery in a vehicle, turn off the ignition, all accessories and loads. Close all the
vehicle doors and the trunk lid.
Make sure you have put 1.5V x 6 pcs internal batteries into the tester (lf the LCD screen shows
"POWER LOW", then the internal batteries need to be replaced).
Clamp the black load lead to the vehicle negative battery terminal (-). Clamp the red load lead to
the vehicle positive battery terminal (+).
BATTERY TEST
Press
ENTER
button to confirm and return to the main interface
STANDARD
JIS:
Japanese Standard
SAE: United States Standard
EN:
European Standard
DIN: German Standard
CA:
Normal starting current or maritime starting current
IEC: lnternational electrical science and technology association
TESTING RANGE
JIS:
40 - 2000 CCA
SAE: 40 - 2000 CCA
DIN: 25 - 1300 CCA
CA:
240 - 1400 CA (MCA)
EN:
40 - 2100 CCA
IEC: 30 - 1500 CCA
The value will rise or fall five units each time, JIS every time for a unit:
SOH: State of health
SOC: State of charge
BATTERY TEST
XX.XX V
[ENTER]
BATTERY TYPE
REGULAR LIQUID
[ENTER]
BATTERY TYPE
AGM
[ENTER]
BATTERY TYPE
VRLA / GEL
[ENTER]
Rating
Standard
JIS
[ENTER]
RATING
Standard
SAE
[ENTER]
RATING
Standard
CA
[ENTER]
RATING
Standard
EN
[ENTER]
RATING
Standard
DIN
[ENTER]
RATING
Standard
IEC
[ENTER]
RATING
CAPACITY
XXX JIS
[ENTER]
GOOD PASS
YES
[ENTER]
SOH XX%
[ENTER]
SOC XX%
[ENTER]
IR XX.XX mΩ
[ENTER]
PRINT RESULT
YES
[ENTER]
PRINT RESULT
NO
[ENTER]