54
Troubleshooting
AkkuMAB 3000
ENGLISH
Troubleshooting
Fault causes and remedies
Fault
Possible cause
Remedy
The motor does not start
after pressing the ON/
OFF switch or stops during
operation.
Rechargeable battery not
inserted.
Insert the rechargeable battery.
Rechargeable battery not
charged.
Charge the battery.
The safety electronics
switched off the battery to pro-
tect it against total discharge.
Insert the battery into the
charging device to recharge.
The rechargeable battery is
reactivated.
The safety electronics
switched off the recharge-
able battery to protect it from
overheating.
Allow the rechargeable battery
to cool down. After it has cooled
down, put it back into the charg-
ing device. The rechargeable
battery is reactivated.
The automatic circuit
breaker in the electrical
distribution board trips.
Too many appliances con-
nected to the same power
circuit.
Reduce the number of appli-
ances on the power circuit.
Charging device is defective.
Contact customer service.
The magnetic clamp does
not function.
Magnet not switched on.
Switch on the magnet.
The surface is not magnetic.
Use a suitable base.
The lubrication system
does not function.
No lubricant available.
Top up the lubricant.
Lubricant tap closed.
Open the lubricant tap.
Connecting nipple clogged.
Clean the tank and nipple.
NOTE
If you cannot resolve the problem with the steps described above, please contact
►
customer service.