background image

   

USER MANUAL     

5

MAINTENANCE

NOTICE: 
Use high grade hydraulic oil only. Never use brake fluid, motor oil, 

transmission fluid, turbine oil or any other fluids. 
ISO-VG22 or equivalent hydraulic oil is recommended.

CHECK AND REFILL OIL

To check oil level, place the pump unit in an upright position. As 

indicated on the diagram opposite. Remove the dip stick and the oil 

level will be indicated. If required add hydraulic oil until it is leveled 

with the full mark on the stem.  As indicated in fig.3

Full replacement of oil is recommended every year for maximum life.To 

drain, remove the dip stick and open release valve. Ensure that no dirt 

gets into the system. Refill with approved high grade hydraulic oil.

LUBRICATION AND CLEANING 

Periodically clean and lubricate all moving parts and pivot points. A periodic light coating of lubricant to all 

moving parts will help prevent the development of rust.

AIR VENTING PROCEDURES 

Occasionally, air bubbles become trapped inside the equipment, reducing its efficiency. Bleed air out of the 

equipment’s hydraulic system as follows: 
1.  Open release valve, remove dip stick. 
2.  Operate pump rapidly several times to force air out. Some oil could splatter. 
3.  Close release valve, replace dip stick. 

The equipment should now operate normally. If not, repeat purging procedure as needed.

DAMAGED EQUIPMENT 

Any equipment that appears to be damaged in any way, is found to be worn, or operates abnormally SHALL 

BE REMOVED FROM SERVICE UNTIL REPAIRED. It is recommended that necessary repairs be made by a 

manufacturers or supplier’s authorized repair facility if repairs are permitted by the manufacturer or supplier. 

ALTERATIONS 

Because of potential hazards associated with this type of equipment, no alterations shall be made to the 

product. 

ATTACHMENTS AND ADAPTERS 

Only attachments and/or adapters supplied by the manufacturer shall be used.

Dipstick

Fig. 3

Summary of Contents for 35.100.004

Page 1: ...of any potential injury hazards Please follow all instructions that follow this symbol to avoid possible injuries or death Indicates a hazardous situation If proper steps are not followed death or se...

Page 2: ...nguage by the purchaser owner or his designee making sure that the operator comprehends their contents This Portable Power Body Repair Kit meets or exceeds ASME PASE 2014 standards IMPORTANT READ ALL...

Page 3: ...astened the couplings before pumping Firmly close the release valve A by turning it in a clockwise direction Fig 1 Attachment Combinations The pump unit can be used with the multi directional ram This...

Page 4: ...4 USER MANUAL SUGGESTED SYSTEM ASSEMBLIES...

Page 5: ...oving parts will help prevent the development of rust AIR VENTING PROCEDURES Occasionally air bubbles become trapped inside the equipment reducing its efficiency Bleed air out of the equipment s hydra...

Page 6: ...AL WITH NEW ONE INSPECTION STORAGE TROUBLESHOOTING INSPECTION TROUBLESHOOTING STORAGE Owners and or operators should be aware that repair of this equipment may require specialized knowledge and facili...

Page 7: ...d 1 12 Plunger toe 1 13 Ram toe 1 14 Base plate 1 15 Male connector 1 16 Ram unit 1 17 4 ton pump unit 1 18 Hydraulic hose 1 REF DESCRIPTION QTY 2 Extension bar 1 1 3 Extension bar 2 1 4 Extension bar...

Page 8: ...the benefits of this warranty contact the dealer or retailer where the unit was purchased For further assistance you can contact BE AG INDUSTRIAL at warranty brabereq com for confirmation that this wa...

Page 9: ...ification de s curit Ce symbole vous informera de tout risque potentiel de blessure Respectez toutes les instructions qui accompagnent ce symbole pour viter tout risque de blessure ou de mort Indique...

Page 10: ...i taire ou son repr sentant en veillant ce que l op rateur comprenne leur contenu Ce kit de r paration de carrosserie portable respecte ou d passe les normes ASME PASE 2014 IMPORTANT LISEZ TOUTES LES...

Page 11: ...montre Fig 1 Combinaisons d accessoires L unit de pompe peut tre utilis e avec le v rin multidirectionnel Cela permet de nombreuses combinaisons d accessoires Appliquez une pression sur la pompe B en...

Page 12: ...S DE SYST ME SUGG R S Plaque de base Plaque de base Plaque de base Extension Pompe B lier en caoutchouc B lier en caoutchouc B lier en caoutchouc Orteil du piston B lier B lier Base de coup de b lier...

Page 13: ...s des bulles d air se retrouvent pi g es l int rieur du cric r duisant son efficacit Purger l air du syst me hydraulique du cric comme suit 1 Ouvrir la soupape de d charge retirer la jauge 2 Faire fon...

Page 14: ...IVEAU CORRECT L UNIT DE CRIC EST INSTABLE SOUS CHARGE LE JOINT DE LA POMPE POURRAIT TRE US REMPLACER LE JOINT DE TASSE PAR UN NOUVEAU INSPECTION STORAGE TROUBLESHOOTING INSPECTION Les propri taires et...

Page 15: ...de b lier 1 14 Plaque de base 1 15 Connecteur m le 1 16 Unit de b lier 1 17 Unit de pompe de 4 tonnes 1 18 Tuyau hydraulique 1 R F DESCRIPTION QUANTIT 2 Barre d extension 1 1 3 Barre d extension 2 1...

Page 16: ...avantages de cette garantie contactez le revendeur ou le d taillant o l unit a t achet e Pour obtenir de l aide vous pouvez contacter BE AG INDUSTRIAL l adresse warranty brabereq com pour confirmer q...

Page 17: ...USER MANUAL 17...

Page 18: ...18 USER MANUAL PARTS BRABEREQ COM TOLL FREE PHONE NUM RO DE T L PHONE SANS FRAIS 1 877 588 3311...

Reviews: