Page 14
WARNING!
Take extra care when raising and lowering the beam as it is fairly heavy. Having a
second person assist with raising or lowering the beam is recommended. Be sure to keep hands
away from any possible pinch points.
STEP 7:
Connect the open ends of the hydraulic hoses to their corresponding fittings. See FIGURE 11.
There are three hydraulic hoses listed below, each of them has one end fixed on the link part assembly at the
manufacturer’s field, the other open end needs you to attach. For clear view of the hydraulic hoses, the hose
protective springs are not shown in the illustration below.
1. Oil suction hose / Ø25 x 310 mm, labeled as
①
, comes from the tank.
Loosen the hose clamp / Ø30 on the open end of this hose, then connect the hose to the fitting on the bottom of the
pump, which is labeled of a same
①
. Tighten the hose clamp.
2. Pump / Valve connecting hose / Ø19 x 900mm, labeled as
②
, comes from the bottom of the valve.
Screw the open end of this hose onto the fitting on top of the pump, which is labeled of a same
②
.
3. Oil return hose / Ø19 x 1500mm, labeled as
③
, comes from the top of the valve.
Loosen the hose clamp / Ø25 on the open end of this hose, then connect the hose to the fitting on the filter, which is
labeled of a same
③
.Tighten the hose clamp.
.
Valve
Filter
Pump
(FIGURE 11)
Hose
Clamp
Ø25
Hose
Clamp
Ø30