background image

If you need assistance with the assembly 

or operation of your Generator please call

 

1-866-850-6662

THE POWER YOU NEED.

Summary of Contents for BE-12000ER

Page 1: ...User Manual BE 12000ER PORTABLE GAS GENERATOR BEPOWEREQUIPMENT COM ...

Page 2: ...hoke Valve 21 Start The Generator 22 Start The Generator Recoil Start 22 Open The Choke Valve 23 Connect To Load Stopping the Generator 23 Disconnect Load 23 Turn Off The Engine Switch 24 Close The Fuel Valve Lever Storage 24 Drain The Fuel 24 Protective Treatment Transporting 25 Transporting Accessories 26 Accessory Installation 26 Two Wheel Short Axle Maintenance 27 Maintenance Chart 28 Replace ...

Page 3: ...safety requirements to the operating functions of your machine You can refer back to the manual at any time to help troubleshoot any specific operating functions so store it with the machine at all times Attention Read through the complete manual prior to the initial use of your generator Record Identification Numbers Generator If you need to contact an Authorized Dealer or Customer Service line 1...

Page 4: ...the generator at least 1 meter 3 feet away from any structure or building during use NEVER use a generator indoors including in homes garages basements crawl spaces and other enclosed or partially enclosed areas even with ventilation Opening doors and windows or using fans will not prevent carbon monoxide build up in the home NEVER use a generator in enclosed or partially enclosed spaces Generator...

Page 5: ...und and can be ignited by the appliance s pilot light or by arcing from electric switches in the appliance WARNING The GFCI may not function unless the generator is properly grounded Follow the correct procedure specified in the section labeled GROUNDING INSTRUCTIONS GROUND FAULT CIRCUIT INTERRUPTER PROTECTION These generators are equipped with a GFCI Ground Fault Circuit Interrupters 120V duplex ...

Page 6: ... generator may become overheated if it is enclosed If generator has been covered to protect if from the weather during non use be sure to remove it and keep it well away from the area during generator use Operate the generator on a level surface It is not necessary to prepare a special foundation for the generator However the generator will vibrate on an irregular surface so choose a level place I...

Page 7: ...red in a dry and well ventilated area Always switch off generator s AC circuit breaker and disconnect tools or appliances when not in use before servicing adjusting or installing accessories and attachments Make sure the engine is stopped before starting any maintenance servicing or repair NOTE Make sure maintenance and repair of the generator are performed by properly trained personnel only SAVE ...

Page 8: ... but switch on another one after stable operation of one electric device AC Circuit Breaker It will break to protect the electric device when current is too heavy Output Indicator It is to indicate power supply status The indicate will brighten up when the equipment operation DC Output The output DC is 12V with maximum of 8 3A It is only used for automotive battery charging with rated 12V Pay atte...

Page 9: ...on use of the generator leave the switch off Chock Valve It is to control air flow into the cylinder when starting up the engine As to the operating method refer to Page 22 Muffler It is to eliminate noise during equipment operation and discharge high temperature exhaust of engine s combustion Do not touch it to avoid burning Timer The Timer records the running time of the generator Press conversi...

Page 10: ...x H mm 800 x 620 x 650 Capacity of Fuel Tank 12 Gal 48L NOISE according to European Directive 2000 14 EC with amendment 2005 88 EC Measured Sound Pressure Level 78 dB A Measured Sound Power Level 98 dB A Uncertainty 2 dB A Guaranteed Sound Power Level 100 dB A Shift the machine outdoors use wire of no less than 2 5mm to make the machine and grounding terminal connected to the ground One end of the...

Page 11: ... closed position and half closed position in thermal state If the generator unit is not started for two times in succession move the choke valve to the open position and then to operate the switch or hand pull starter Press it to START if its electrical start state then generator can be started In order to extend the service life of the storage battery do not press on the switch for more than 3 se...

Page 12: ...breaker to ON Please note that when several loads are used at the same time do not access the next one unless the former one is running normally The total power of the loads should not exceed the rated power of the unit Disconnect the electric equipment from the control panel of the generator After 30 seconds of no load running turn off the engine switch and the generator unit will be shut down im...

Page 13: ...c bag to prevent dust from entering the unit Transporting WARNING Do not overfill the tank Do not operate the generator while it is on a vehicle Take the generator off the vehicle and use it in a well ventilated place Avoid a place exposed to direct sunlight when putting the generator on a vehicle If the generator is left in an enclosed vehicle for many hours high temperature inside the vehicle co...

Page 14: ...th 3 Every 50hrs or 3 Months 3 Every 100hrs or 6 Months 3 Every 300hrs or each Year 3 Engine Oil SAE 10W30 Inspect the oil level X Replace oil and filter X X Air Cleaner Inspect X Clean X 1 Fuel Switch Sediment cup Clean X Spark Plug Clean X Replace Valve Clearance Readjust X 2 Cylinder Head Wash Every 300 Hours 2 Fuel Tank and Strainer Wash Every 2 Years 2 Fuel Tube Replace Every 2 Years 2 1 Main...

Page 15: ...4 Inspect the spark plug insulator visually for damage If it is damaged replace a new one 5 Measure the spark plug gap with a gap gauge Twist the side electrode to adjust the gap The gap should be kept between 0 70 and 0 80mm 6 Inspect if the washer of the spark plug is in good condition 7 Reinstall the spark plug and tighten it with the spark plug socket spanner Press down the washer of the spark...

Page 16: ...t The circuit breaker is not connected Turn the circuit breaker to the on position The plug is poorly contacted Replace a socket Vibration while operation The choke position is incorrect Move the choke to the on position Vibration while operation The temperature of the engine is too low Let the engine run at empty load for more than 10 mins The fuel oil is contaminated Replace clean oil The genera...

Page 17: ... environment conditions are inconsistent with the above standards or if the cooling conditions of the engine and generator set are defective for example when running in limited areas it is necessary to reduce the power It is also necessary to reduce the power when the temperature altitude and relative humidity exceed the standards If there is no problem with the conditions above please turn to the...

Page 18: ...34 35 ELECTRICAL SCHEMATIC DIAGRAM 2 60HZ 120V 240V DIAGRAMS ...

Page 19: ...If you need assistance with the assembly or operation of your Generator please call 1 866 850 6662 THE POWER YOU NEED ...

Reviews: