1
max. 5 cm
2
3
2.2 m
2.2 m
2.2 m
2.2 m
MOUNTING & WIRING
RADAR OPENING IMPULSE FIELD
ANGLE
WIDTH
4 m x 2 m (wide)
2 m x 2.5 m (narrow)
field size: 9
immunity: 2
field size: 9
immunity: 2
field size: 9
immunity: 2
field size: 9
immunity: 2
The size of the detection field varies according to the mounting height of the sensor.
In emergency exits the full door width must be covered.
from 15° to 45°, default 30 °
from -15° to 15°, default 0°
ENGLISH
IXIO-D CAN: INSTALLATION GUIDE
Plug the connector with the WHITE and GREEN
wires on top towards the sensor cover.
GREEN
BROWN
+
-
POWER SUPPLY
CAN HIGH
CAN LOW
YELLOW
WHITE