DIN 18650
BS 7036
EN 16005
3,50 m
3 m
2,50 m
2 m
d max = 2,5 m
d max = 3 m
3,50 m
3 m
2,50 m
2 m
max.
9 cm**
4
2x
W W
W
N
N
W
N N
address 4
address 0
address 1
address 8
address 9
address 10
address 11
address 12
address 13
address 14
address 15
address 2
address 3
address 5
address 6
address 7
WIDTH
TIP!
Additional
adjustments
are possible
(see p. 6)
Part of the detection field can be masked to reduce it.
The arrow position determines the width of the detection field.
INFRARED SAFETY FIELD
CLOSER
AWAY
If necessary, adjust the IR-curtain
angle (from -7° to 4°, default 0°).
Activate the visible* spots to verify
the position of the IR-curtain.
ANGLE
* Visibility depends on external conditions. When spots are not visible, use the Spotfinder to locate the curtains.
** The distance between the inner curtain of the inside door sensor and the inner curtain of the outside door sensor should
always be smaller than 20 cm. The distance to the door leaf depends therefore on the thickness of the door leaf.
The size of the detection field varies according to the
mounting height and the settings of the sensor.
The full door width must be covered.
Mounting
height
Detection
width
2.00 m
2.20 m
2.50 m
3.00 m
3.50 m
2.00 m
2.20 m
2.50 m
d max
d max
Always verify the actual detection field width
with a piece of paper and not the Spotfinder,
which detects the whole emitted field.
3.50 m
3 m
2.50 m
2 m
d max = 2.5 m
3.50 m
3 m
2.50 m
2 m
DOOR
DIP-SWITCH 1-4: CAN-ADDRESS
SENSOR 1
SENSOR 2
SENSOR 3
SENSOR 4
SENSOR 5
SENSOR 6
SENSOR 7
SENSOR 8
SENSOR 9
SENSOR 10
SENSOR 11
SENSOR 12
SENSOR 13
SENSOR 14
SENSOR 15
SENSOR 16
DIP-switches: each sensor needs a different CAN address depending on its position.
After changing a DIP-switch, the orange LED flashes quickly. Cut and restore power supply to confirm the setting.