MOUNTING & WIRING

WIRING TO MICROCELL

If using dry contact safety beams, such as BEA’s Microcell, remember these changes:

•  Power the safety beams with the same transformer that is used for the LO-21.  
•  The black/white striped wire is not used and should be taped off.  
•  The gray and purple wires of the LO-21 go to the NO and COM dry contacts of the safety beams.  

All LO-21 wiring must be accomplished with the module unplugged. If the red / white striped and white 
wires (data wires) touch each other when power is applied, damage to the unit will result. 

HYDRAULIC UNIT / AC MOTOR

If AC voltage is > 50 VAC, use the provided 10,000 Ohm resistor to wire in-line with the red wire.

Below are examples of a Keane Monroe Series 2000 swing-door operator.

WIRING TO HYDRAULIC UNIT

WIRING TO AC MOTOR

*  If using safety beams, blue and green wires must be wired in parallel with 

the Bodyguard/DK-12 connection to the SAF and COM of the door control.

white

= required connection

= optional connection for 
   photo beams

green

red/white

white

gray

purple

re

d

black

re

d

black

yellow

green*

blue*

brown

orange

DATA +

DATA -

NC

NO

COM

PWR

PWR

7

6

5

4

3

2

1

LO-21

LOCK-OUT

 RELAY

DK-12/Bodyguard

24 V TRANSFORMER

+

-

DOOR

CONTROL

DC

MOTOR

SAFETY

NOT

USED

115 VAC

MOTOR

MOTOR

MICROCELL

LO-21

LOCK-OUT

 RELAY

MOTOR

white

orange

10K RESISTOR

TO DOOR CONTROL

red

black

LO-21

LOCK-OUT

 RELAY

AC MOTOR

orange

white

10K RESISTOR

red

black

SOLENOID WIRES

(TYPICALLY RED OR BLACK)

Summary of Contents for LO-21

Page 1: ...pletion of installation DO NOT attempt any internal repair of the components All repairs and or component replacements must be performed by BEA Inc Unauthorized disassembly or repair 1 May jeopardize personal safety and may expose one to the risk of electrical shock 2 May adversely affect the safe and reliable performance of the product resulting in a voided warranty Always test the proper operati...

Page 2: ...AC voltage is 50 VAC use the provided 10 000 Ohm resistor to wire in line with the red wire Below are examples of a Keane Monroe Series 2000 swing door operator WIRING TO HYDRAULIC UNIT WIRING TO AC MOTOR If using safety beams blue and green wires must be wired in parallel with the Bodyguard DK 12 connection to the SAF and COM of the door control white required connection optional connection for p...

Page 3: ...nging DIP switch settings These can be set for a time delay of 0 31 seconds See following page for specific DIP switch settings Time Delay begins when motor starts rotating to close door Time Delay DOES NOT stop counting if motor rotation stops Time Delay is only interrupted when door reactivates or safety beams are broken must be set to ensure that red LED remains on for entire door closing cycle...

Page 4: ...1 Incorrect wiring at LO 21 Verify correct polarity at terminals 6 and 7 on Bodyguard Faulty LO 21 If data line voltage remains constant at LO 21 for open and close dpositions and all wiring verified replace faulty LO 21 BEA Original Instructions PLEASE KEEP FOR FURTHER USE DESIGNED FOR COLOR PRINTING BEA the sensor manufacturer cannot be held responsible for incorrect installations or inappropria...