WIRING

80.0185

BESAM 300/400 (ETIK2) WITH LO21P PARALLAX II SYSTEM Q-DISCONNECT ON APPROACH SIDE

80.0186

BESAM 300/400 (ETIK2) WITH LO21P PARALLAX II SYSTEM Q-DISCONNECT ON SAFETY SIDE

80.0187

STANLEY MP CONTROL WITH LO21P PARALLAX II SYSTEM Q-DISCONNECT ON APPROACH SIDE

80.0188

STANLEY MP CONTROL WITH LO21P PARALLAX II SYSTEM Q-DISCONNECT ON SAFETY SIDE

80.0193

BESAM CUP VER. 6.3, 6.4 CONTROL WITH LO21P PARALLAX II SYSTEM Q-DISCONNECT ON 
APPROACH SIDE

80.0194

BESAM CUP VER. 6.3, 6.4 CONTROL WITH LO21P PARALLAX II SYSTEM Q-DISCONNECT ON 
SAFETY SIDE

May be used on most models of operators.

red

black
yellow
green
blue

DATA+ 7

AUTO

+

-

1 15 VAC

brown

orange

purple

gray

white

red / white

black / white

24 V

TRANSFORMER

OPERATOR

OFF

HOLD

MOTOR

SAFETY
COMMON
ACTIVATION

Contacts to open
at desired point of
inhibiting

STALL

DOOR CONTROL

DATA- 6
N.C. 5
N.O. 4
COM 3
POWER 2
POWER 1

1  2  3  4  5  6  7  8

1 2 3 4 5

8  7  6  5  4  3  2  1

LO21P

Stall SUPERSCAN

(Swing Side)

Approach

SUPERSCAN

NOTE:
LO21P DIPSWITCH SETTINGS:
#1 THROUGH #5 - SET FOR
REQUIRED LOCKOUT TIME

#6 ON, #7 OFF, #8 ON

NOTE: BODYGUARD MUST be programmed 
to a Relay Output value of 2. Default is 1.

BODYGUARD

EAGLE

Scan QR code for additional LO21P wiring diagrams.
Use the table below to easily search for your desired wiring diagram.

Summary of Contents for LO21P

Page 1: ...hen working in public areas Constantly be aware of pedestrian traffic around the door area Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires and cause damage to equipment Ensure compliance with all applicable sa...

Page 2: ...utside of its intended purpose BEA Inc strongly recommends that installation and service technicians be AAADM certified for pedestrian doors IDA certified for doors gates and factory trained for the type of door gate system Installers and service personnel are responsible for executing a risk assessment following each installation service performed ensuring that the sensor device system performanc...

Page 3: ... II SYSTEM Q DISCONNECT ON SAFETY SIDE May be used on most models of operators red black yellow green blue DATA 7 AUTO 1 15 VAC brown orange purple gray white red white black white 24 V TRANSFORMER OPERATOR OFF HOLD MOTOR SAFETY COMMON ACTIVATION Contacts to open at desired point of inhibiting STALL DOOR CONTROL DATA 6 N C 5 N O 4 COM 3 POWER 2 POWER 1 1 2 3 4 5 6 7 8 1 2 3 4 5 8 7 6 5 4 3 2 1 LO2...

Page 4: ...nits Correct any faults before proceeding If the BODYGUARD T learns a door closed position but does not execute a setup for the door open position place the door in a hold open position With the Universal Remote Control unlock the BODYGUARD T and with the door in the open position press the Magic Wand key and then 2 The BODYGUARD T should begin flashing green to signify a setup If it does not this...

Page 5: ...DYGUARD T s and LO21P s red LEDs should illuminate and remain on as soon as the door reaches the fully closed position provided that an object remains in the BODYGUARD T s detection zone 9 Set the DIP switches according to the chart below to achieve the desired lock out time The total lock out time is the sum total of the DIP switches that are in the ON position For easy reference use the timetabl...

Page 6: ...FF ON OFF 9 ON OFF OFF ON OFF 10 OFF ON OFF ON OFF 11 ON ON OFF ON OFF 12 OFF OFF ON ON OFF 13 ON OFF ON ON OFF 14 OFF ON ON ON OFF 15 ON ON ON ON OFF 16 OFF OFF OFF OFF ON 17 ON OFF OFF OFF ON 18 OFF ON OFF OFF ON 19 ON ON OFF OFF ON 20 OFF OFF ON OFF ON 21 ON OFF ON OFF ON 22 OFF ON ON OFF ON 23 ON ON ON OFF ON 24 OFF OFF OFF ON ON 25 ON OFF OFF ON ON 26 OFF ON OFF ON ON 27 ON ON OFF ON ON 28 OF...

Page 7: ...N HORTON 7000 ON OFF ON KM 2000 ON OFF ON STANLEY MAGIC SWING MAGIC FORCE with safety ON OFF ON DIP 6 ON LO21P expects incoming voltage at the red and black wires while the door is in the open position Typical for DC motors OFF LO21P expects incoming voltage at the red and black wires while the door is in the closed position DIP 7 DIP 8 OFF ON LO21P closes safety circuit yellow wire upon BODYGUARD...

Page 8: ...nd LO21P Door will not close On Off Hold Open switch is in hold open position Place switch in On or Auto position BODYGUARD T is in detection Launch a setup at BODYGUARD T Faulty door control Remove wire from COM and ACT terminal at door control If door does not close replace or repair the faulty control Bodyguard keeps re learning with each door position Incorrect data polarity at BODYGUARD T Ens...

Reviews: