8
cm
>
>
ms
cm
cm
10
20
25
30
35
40
45
50
5
15
374
324
299
274
250
400
349
5
10
15
20
25
30
35
40
8
*
The sensor will automatically launch teach-in with every adjustment. Please leave the detection field
and make sure it is clear before the teach-in process begins.
Min. object size: we guarantee all objects above the minimum object size will be
detected, but objects below minimum object size are not always rejected.
MIN. OBJECT
SIZE
Output activation delay: the detection will generate output only when detection lasts
longer than the given number.
OUTPUT
ACTIVATION
DELAY
100
400
500
600
700
800
900
0
200
Fog filter: different values means different max. detection distances with 5% reflectivity.
FOG FILTER*
off
UNCOVERED
ZONE
Uncovered zone: increase in case of snow, dead leaves, etc. Measured in specific
conditions and determined by application and installation.
IMMUNITY
FILTER
Immunity Filter: when there’s interference from environment such as rain, snow which
could create some false detection, occasional false detection could be decreased by
increasing immunity level.
low
no
filtering
FACTORY VALUES
high
300