4
NC
NO
NO
NO
NC
NO
NC
NC
cm
cm
001 - 500
cm
001 - 300
001 - 300
×10cm
1
1
1
1
NO
NC
VPB2
VPB1
VPB1
VPB2
6
Left or right
no field
no field
WIDTH
(right)
no field
Left
PARAMETER SETTINGS
FACTORY VALUES
WIDTH
(left)
HEIGHT
SAFETY
FIELD
PUSH BUTTON
FIELD
A new teach-in overwrites
these values.
R1 (RELAY)
R2 (OPTO)
NO POWER
NO DETECTION
DETECTION
OUTPUT
CONFIGURATION
NO = normally open
NC = normally closed
NO POWER
NO DETECTION
DETECTION
In order to change these settings by remote control, adjust DIP switch 4 to ON.
The LED turns green if there is a detection in VPB areas. The LED turns red if there is a
detection in safety areas. The LED also turns green if there is a detection in both areas.
OUTPUT
REDIRECTION
Left or right
FRONT FACE
Clasp the front cover to finish the installation.
Protect the laser window in case of construction works.
VPB1
WIDTH
VPB1
HEIGHT
VPB2
WIDTH
VPB2
HEIGHT
Example: +
VPB1 (virtual push button 1) size = 20 × 30 cm
VPB 2 (virtual push button 2) size = 30 × 50 cm
VPB2
VPB1
R1(RELAY)
R2(OPTO)
Left or right
NO NC
VPB1 or VPB2
VPB1 or VPB2 VPB1 or VPB2
VPB1 or VPB2