Page 6 of 12
75.5897.02 LZR-H110 20170821
Adjust the tilt angle of the
detection field with the hex key.
Lock the position of the mounting
bracket to avoid malfunctioning in
case of extreme vibrations.
If not, turn the sensor slightly
on its axis to find the correct
position.
Activate the visible laser beams
by remote control. To turn off,
use same sequence. After 15
minutes, the beams switch off.
Verify the lateral position of
the sensor. Make sure the laser
beam is visible on the opposite
pole.
Verify if both beams are on
equal height.
WITH REFERENCE POINT (surface of min. 15 cm)
The sensor will automatically adjust the safety field on
the basis of the reference point if C = 00.
WITHOUT REFERENCE POINT
left
right
left
right
Choose the correct mounting side:
LEFT
or
RIGHT
LEFT
RIGHT
LEFT + REF
RIGHT + REF
POSITIONING (3 SPOTS)
MOUNTING SIDE
3
4
0°
45°
90°
a
d
b
e
c