5
2
3
1
2
3
CAT 2
Adjust the
lateral position
of
the detection field.
Adjust the
tilt angle
of the
detection field with the hex
key.
Lock the position
of the
mounting bracket to avoid
malfunctioning in case of
extreme vibrations.
Unlock the sensor and activate the visible laser beams.
The visible laser beams indicate approximately the postion of the first curtain
and limit the angle of the detection field.
The visible laser beams stay activated for 15 minutes or can be turned off the
same way they were activated.
Door control without test:
connect red and blue wires to power supply (no polarity)
WIRING
POSITIONING
POWER
POWER SUPPLY -
RELAY 1 - OPTIONAL FIELD
RELAY 2 - SAFETY FIELD
TEST +
TEST -
NOT USED
GREEN
BROWN
WHITE
YELLOW
PINK
VIOLET
RED
BLUE
WHITE/RED
WHITE/BLUE
CAUTION!
The distance between the inner curtains of the 2 sensors