background image

 

 

3

Ozone, Spa lights. 

4

CD audio-input / Display of radio frequency and preserve 10 channels 

5

Volume display and 87 frequency adjustment 

6

Circulation cleaning and time set of circulation cleaning 

7

24 hours display and time set 

8

Memory preserve once power off 

9

Fahrenheit & Celsius degree switch 

10

Antifreezing functions 

11

Keys with backlight 

12

Lock setting 

13

Three-phase or single-phase, available

 of 110-120VAC or 220-240VAC

   

14

Choice with “CD” function, 

offering a AC supply for circumscribing DVD or TV

 

15

Choice with power control 

16

Choice with galvanoscope device

 

 

III

Operation

 

             

 

Fig.3

Temperature Normal Display

                        Fig.4

Senor on/short circuit display

 

1

When you first start the spa, the backlight will be dimmed and the LCD will show the current time and 
temperature. If there is a problem with the circuit board the controller will display 

the code “E1”. When 

the  radio  frequency  is  displayed  as 

---

  it  indicates  that  the  spa  is  in 

power  off

  model,  and 

pre-heating and circulation cleaning function is off. 

 

2

Lock memory Mode

(optional function)

 

The memory lock will start work by pressing

 

MEM

  key

 in the status of 

power off

when the 

spa  has  not  been  adjusted  for  a  period  of  30  minutes.  When  the  memory  locked  key  is  pressed  TWICE

 

MEM

  the spa will become 

unlocked and the word 

LOCKED

will disappear. 

3

Adjusting Time

 

In  the 

status  “Power  off

  and  the  pre-heating  and  circulation  cleaning  are  not  starting.  Pressing

 

MIN

or

HOUR

  adjust time . The Minute and Hour display flash at this time. It will add 1 hour when 

pressing

 

HOUR

  each time and the hours can be adjusted continually when pressing the 

HOUR

 

without stopping. The hour adjustment range is 

0-23.

 

In the status of time setting It will add 1 minute when pressing 

MIN

 

each time and the minutes 

Summary of Contents for SPA-520

Page 1: ...1 HOT TUB Model SPA 520 OPERATING INSTRUCTION...

Page 2: ...ry Lock Surfing pump 1 On off SET Radio channel read Close view pump 2 On off Lasting Circulation Cleaning On off Surfing pump3 circulation pump On off Set Circulation Cleaning Time Heating On off Set...

Page 3: ...re If there is a problem with the circuit board the controller will display the code E1 When the radio frequency is displayed as it indicates that the spa is in power off model and pre heating and cir...

Page 4: ...cleaning on When setting the Circulation cleaning the display must be in the Power off status and the LCD display 1 Press to enter Circulation cleaning setting mode and the LCD shows and flashes and t...

Page 5: ...d 55 minutes When you have completed this procedure continue to the next setting 4 If all settings have been correctly set Press for confirmation the system will quit this mode automatically press key...

Page 6: ...ee following Fig 7 8 ON OFF Fig 7 Pre heat On 8 Pre heat Off Pre heating is set when the spa is in the Power off status and the LCD display shows 1 Set preheating 2 Time setting for Preheating 3 Conti...

Page 7: ...Press SET VOL again It will show SET on the LCD panel Press button to change the setting temperature The range of temperature setting is 15 45 5 When everything is set correctly press the to confirm...

Page 8: ...shows the countdown time All the surfing pumps and blower will work for 30 seconds at every 30 minutes The Ozone works at every 15 minutes During the preheating the Circulation cleaning will be turne...

Page 9: ...annel LCD will display Press the key MEM could memorize the present radio frequency Pressing the key MEM continually will memorize the present radio frequency in different channel The channel of max i...

Page 10: ...off pressing the key can change the mode of Fahrenheit Celsius degree 17 When there is no water in the spa All water pumps and heating system can not start up However the corresponding signals will f...

Page 11: ...d be supplied through a residual current device RCD having a rated residual operating current not exceeding 30 mA The floor has to be capable of supporting the expected load An adequate drainage syste...

Page 12: ...nge a new ozonater 2 change a fuse 3 check if the cable of the main power is connected with the main box or not Displaied E1 FF in control panel 1 temperature detector be cut off or shortcirculate 2 p...

Page 13: ...13...

Page 14: ...14...

Page 15: ...15...

Page 16: ...16...