background image

 

 

AM

PUMP3

 

Fig.11

Radio frequency is 105.2 MHZ

Save the present frequency to channel 3 (Save channel)   

or Exchange the frequency form channel 3 to the present (Searching channel) 

 

                         

 

I

  is the ON/OFF key for radio and CD

and it is only available in the status of power on. The 

first pressing 

  is turning on the radio

the second pressing

 

  will turn off the radio and turn 

on the CD at the same time

and the third pressing

 

will turn off the radio and CD simultaneous

 

Ⅱ、

LCD will show present frequency and volume of the radio after turning on the radio

 

Ⅲ、

In the working of radio, the present radio frequency

 

can be changed by pressing

 

MIN

and 

HOUR

 

Ⅳ、

Pressing the key

 “

SET

  will take out the memorized radio frequency

Pressing the key

 

SET

  continually  will take out the memorized radio frequency from  channels  will  be saved at present 

channel by pressing this key continually

If none of the channel

  LCD will display 

---

 

Ⅴ、

Press  the  key

 “

MEM

 ”

  could  memorize  the  present  radio  frequency

  Pressing  the  key

 

MEM

  continually will memorize the present radio frequency in different channel

  The channel of max is 

10

Name of channel is 0-9

 

Ⅵ、

The volume can be changed by pressing key 

SET

VOL+

and

OPEN

 

11

Operation of Pump

 

The  Button 

,  operates  pump  1

The  Button   

PUMP2

operates    pump  2

The  button 

PUMP3

operates  pump  3

When  Circulation  cleaning  and  heating  (including  preheating)  turn  on,  circulation 

pump will be working automatically. 

 

12

Operation of lasting circulation cleaning

 

Press the key 

  at any time to turn on or off the lasting circulation cleaning, work mode is like the 

preset circulation cleaning.    The surfing pumps and blower work for 30 seconds at every 30 minutes. Ozonizer 

works for 15 minutes at every 105 minutes, and repeat in this program. 

  Once any surfing pumps or blower pump be start, the ozonizer without working.    The ozonizer can not 

work if the circulation pump is without working.

   

 

IMPORTANT

: Please ensure that the ozone function is not in use whilst bathing in the spa. 

 

Summary of Contents for SPA-520

Page 1: ...1 HOT TUB Model SPA 520 OPERATING INSTRUCTION...

Page 2: ...ry Lock Surfing pump 1 On off SET Radio channel read Close view pump 2 On off Lasting Circulation Cleaning On off Surfing pump3 circulation pump On off Set Circulation Cleaning Time Heating On off Set...

Page 3: ...re If there is a problem with the circuit board the controller will display the code E1 When the radio frequency is displayed as it indicates that the spa is in power off model and pre heating and cir...

Page 4: ...cleaning on When setting the Circulation cleaning the display must be in the Power off status and the LCD display 1 Press to enter Circulation cleaning setting mode and the LCD shows and flashes and t...

Page 5: ...d 55 minutes When you have completed this procedure continue to the next setting 4 If all settings have been correctly set Press for confirmation the system will quit this mode automatically press key...

Page 6: ...ee following Fig 7 8 ON OFF Fig 7 Pre heat On 8 Pre heat Off Pre heating is set when the spa is in the Power off status and the LCD display shows 1 Set preheating 2 Time setting for Preheating 3 Conti...

Page 7: ...Press SET VOL again It will show SET on the LCD panel Press button to change the setting temperature The range of temperature setting is 15 45 5 When everything is set correctly press the to confirm...

Page 8: ...shows the countdown time All the surfing pumps and blower will work for 30 seconds at every 30 minutes The Ozone works at every 15 minutes During the preheating the Circulation cleaning will be turne...

Page 9: ...annel LCD will display Press the key MEM could memorize the present radio frequency Pressing the key MEM continually will memorize the present radio frequency in different channel The channel of max i...

Page 10: ...off pressing the key can change the mode of Fahrenheit Celsius degree 17 When there is no water in the spa All water pumps and heating system can not start up However the corresponding signals will f...

Page 11: ...d be supplied through a residual current device RCD having a rated residual operating current not exceeding 30 mA The floor has to be capable of supporting the expected load An adequate drainage syste...

Page 12: ...nge a new ozonater 2 change a fuse 3 check if the cable of the main power is connected with the main box or not Displaied E1 FF in control panel 1 temperature detector be cut off or shortcirculate 2 p...

Page 13: ...13...

Page 14: ...14...

Page 15: ...15...

Page 16: ...16...