4233 5000 13
67
The lifetime of the desiccant is related to the operating conditions. The scheduled lifetime
is only valid when operating in reference working conditions. If the desiccant becomes
contaminated due to more severe operating conditions, it will have to be replaced earlier.
It is recommended to have the desiccant replaced by a qualified service technician.
Check periodically that:
•
All safety equipment is in good working order
•
All hoses, cables, wiring, pipes are in good condition, secure and not rubbing
•
There are no leaks
•
All fasteners are tight
•
All electrical leads are secure and in good order
•
Air outlet valves and manifold, hoses, couplings, … are in good shape and free of wear or
abuse
7.3 Service kits
Service kits
Service kits are available, offering the benefits of genuine parts while keeping the maintenance
budget low. The kits comprise all parts needed for servicing.
A complete survey of available service kits is given in the Spare Parts Book.
Warning
The service kits must be installed by trained and certified personnel.
7.4 Storage after installation
Procedure
When the desiccant is in good shape, stop the unit and keep all valves closed to avoid moisture
from entering the unit.
Keep the air treatment unit and its spare parts away from materials which easily oxidise
(e.g. peroxides, chlorates, acids, …).
Spare parts must be stored in dry, cool and closed containers.
Although the unit does not contain hazardous substances, it must be handled with care
under any condition.
Summary of Contents for dMED 025