4233 5000 13
81
10.4 Reference conditions and limitations
Reference conditions
Units
Compressed air inlet pressure
bar(e)
See Technical data
Compressed air inlet pressure
psig
See Technical data
Compressed air inlet temperature
˚C
35
Compressed air inlet temperature
˚F
95
Ambient temperature
˚C
5 to 50
Ambient temperature
˚F
41 to 122
Inlet relative air humidity
%
95
Pressure dew point
°C
-40
Pressure dew point
°F
-40
Limitations
Units
Maximum compressed air inlet pressure
bar(e)
14
Maximum compressed air inlet pressure
psig
203
Minimum compressed air inlet pressure
bar(e)
4
Minimum compressed air inlet pressure
psig
58
Maximum concentration of contaminants:
O
2
concentration
%
20 < x < 22
CO
2
concentration
ppm
700
SO
2
concentration
ppm
5
NO
x
concentration
ppm
5
Water vapour amount
%
100
Oil vapour amount
mg/m
3
3
10.5 Technical data
Data at 7 bar inlet pressure
Unit
dMED
025
dMED
035
dMED
045
dMED
075
dMED
090
Volume flow at dryer inlet
l/min
710
990
1220
2120
2550
Volume flow at dryer inlet
cfm
25.5
36
44.5
74.2
89
Pressure drop over dryer
mbar
646
926
722
757
644
Pressure drop over dryer
psi
9,37
13,4
10,47
10.98
9.34
Time of half a cycle
s
154
154
154
154
154
Regeneration time
s
120
120
120
120
120