4233 5000 13
83
Data at 10 bar inlet pressure
Unit
dMED
025
dMED
035
dMED
045
dMED
075
dMED
090
Volume flow at dryer inlet
l/min
960
1360
1760
2920
3480
Volume flow at dryer inlet
cfm
33.9
48.7
61.4
103.8
122.9
Pressure drop over dryer
mbar
646
926
722
757
644
Pressure drop over dryer
psi
9,37
13,4
10,47
10.98
9.34
Time of half a cycle
s
154
154
154
154
154
Regeneration time
s
120
120
120
120
120
Pressurization time
s
34
34
34
34
34
Installed power
W
340
340
340
340
340
Net mass
kg
220
240
280
320
360
Net mass
lb
485
529
617
703
794
Air quality (Pharmacopeia)
•
O
2
concentration
%
20<X<
22
•
CO
2
concentration
ppm
500
•
CO concentration
ppm
5
•
SO
2
concentration
ppm
1
•
NO
x
concentration
ppm
2
•
Pressure dew point
°C
-31
•
Pressure dew point
°F
-23.8
•
Oil vapour
mg/m³
0.1
•
Taste and odour
free
Unit
dMED
110
dMED
150
dMED
220
dMED
300
Volume flow at dryer inlet
l/min
4280
5830
8520
11640
Volume flow at dryer inlet
cfm
150.4
192.8
300.8
411
Pressure drop over dryer
mbar
660
700
820
800
Pressure drop over dryer
psi
9,57
10,15
11,89
11,60
Time of half a cycle
s
154
154
154
154
Regeneration time
s
120
120
120
120
Pressurization time
s
34
34
34
34
Installed power
W
340
340
340
340
Net mass
kg
450
510
650
760
Net mass
lb
992
1124
1433
1675
Air quality (Pharmacopeia)
•
O
2
concentration
%
20<X<
22
•
CO
2
concentration
ppm
500
•
CO concentration
ppm
5
Summary of Contents for dMED 025