Operating instructions
Safety
Always observe all relevant safety instructions.
Startup valve positions
1
Inlet Valve (Closed)
2
Outlet Valve (Open)
3
DP sensor valve (Closed)
4
2 x Link valve (Open)
5
Drain Valve (Closed)
6
Full flow test point valve (Closed)
7
Sampling point Valve (Closed)
8
Sensor maintenance valve (Open)
9
Line Valve (Closed)
10
PD flow control valve (Leave as set)
Note – Item 3 (PD sensor valve) is for diagnostics only. When closed the dew point reading is taken from line. By
opening this valve, you can read the dewpoint between the dryer column and QDT filter. This allow you to determine if
a dew point fault is due to the dryer column not performing or the QDT has become saturated.
1
2
3
4
6
7
5
8
9
10