19
Part No. 6-847684-00 Rev. D01
Wiring Schematic 6: General Fault / Auxiliary Relays
Wiring Schematic 7: Digital Display Module High / Low Relays
Annunciator Module
Digital Display Module
ribbon to
adjacent
module
General Fault Relay
N/C (pin 5)
N/O (pin 3)
Common (pin 4)
N/O (pin 6)
Common (pin 7)
N/C (pin 8)
Auxiliary Relay
NOTE:
General Fault Relay activates when ANY
alarm on panel is in progress. Pressing
MUTE
on Annunciator Module DOES
NOT reset relay. Relay deactivates when
alarm condition is corrected.
Auxiliary Relay (optional) activates when
ANY audible alarm on panel is in progress.
Pressing MUTE
on Annunciator Module
WILL deactivate relay until audible alarm is
again reactivated.
Relay contact ratings are 2A @ 30 VDC/0.5
A @ 125 VAC.
ribbon to
adjacent
module
Low Alarm Relay
N/C (pin 8)
Common (pin 7)
N/C (pin 10)
Common (pin 9)
High Alarm Relay
NOTE:
High Alarm Relay activates when high line
pressure alarm on digital display module is
in progress. When relay activates normally
closed contacts open. Pressing MUTE
on Annunciator Module DOES NOT deacti-
vate relay. Relay deactivates when high line
pressure alarm condition is corrected.
Low Alarm Relay activates when low line
pressure alarm on digital display module is
in progress. When relay activates normally
closed contacts open. Pressing MUTE
on Annunciator Module DOES NOT deacti-
vate relay. Relay deactivates when low line
pressure alarm condition is corrected.
Relay contact ratings are 2A @ 30 VDC/0.5
A @ 125 VAC.