7. TROUBLE SHOOTING 

Problem 

Possible Cause 

Action to Take 

UPS no reaction while AC 
is connected 
 
 
 

1.  Line cord plug is loose 
2.  Fuse on rear panel blown

(Inside the drawer of inlet)

3.  Dead wall socket 

1. Check the line cord plug 
2. Replace fuse 
3. Check wall socket with a table 

lamp. 

Power output is normal, UPS 
emits continuous beep, status 
LED shows RED. 
 

UPS is over loaded 

Turn off UPS and unplug 

excessive loads from UPS. 

UPS does not provide 
expected run time 

1. Excessive loads connected 

at UPS outlets. 

2. Battery is weak and 

cannot provide enough 
capacity. 

Do not operate the UPS, and 
leave the UPS plugged in for 10 
hours.    Then, test it again, if UPS 
still cannot provide expected run 
time, battery should be replaced. 
 

Button on front panel 
doesn’t work 

1. The CPU inside UPS is 

not running correctly. 

2. Button damaged. 

1. Push the button for 6 seconds 

to reset the UPS. 

2.Unplug line cord and all loads 

from the UPS, and call for 
service. 

 

Under AC mode, UPS emits 
urgent beep (8 beeps per 
sec.) and LED of “Replace 
Battery” comes on. 
 

Battery is weak and should 
be replaced 

Replace batteries. 

No output when blackout 
happen. 
 
 

1. Dead battery. 
2. UPS NG. 

1. Replace battery. 
2. Call for service. 

 
 
 

Summary of Contents for BS-1200

Page 1: ...UPS AVR Uninterruptible Power System User s Manual Back up Series BS 600 1200 1700 2000 Replace Battery Alarm Off Charging B u c k Boost BATTERY LEVEL SPECIAL STATUS NORMAL BACK UP LOW BATT OVER LOAD ...

Page 2: ...AUTION Page 3 4 INSTALLATION AND OPERATION Page 4 4 1 Installation 4 2 Operation 5 INDICATION AND CONTROL Page 5 6 5 1 Battery level LEDs 5 2 Special status LEDs 5 3 Auto self test function 5 4 Status LED and Alarm indication 5 5 Reset the UPS 6 COMMUNICATION INTERFACE Page 6 7 TROUBLE SHOOTING Page 7 8 SPECIFICATIONS Page 8 9 IMPORTANT SAFETY INSTRUCTIONS Page 9 ...

Page 3: ...eration status Control button Rear Panel Fuse Inlet of city power RS 232 port DB 9 Outlets NEMA IEC 2 1 4 NORMAL BACK UP LOW BATT OVER LOAD BATTERY LEVEL SPECIAL STATUS Replace Battery Alarm Off Charging B u c k Boost 100 80 60 40 20 3 1 3 2 4 4 NEMA Type IEC Type 2 1 3 4 2 1 3 4 ...

Page 4: ... mode function Auto detect input frequency 50Hz 60Hz Self test function Battery replacement indication Extra wide range AVR function Standard RS 232 port for monitoring function Double protections for over load short circuit 3 CAUTION The UPS is designed to power computer loads and the associated peripheral devices such as monitors modems external H Disk drivers etc To ensure the performance of th...

Page 5: ...en blackout happens LED of operation status will become red and alarm will beep if the load is over the rated value Meantime if the overload is severe the UPS will shut down immediately for protecting UPS itself 4 2 Operation 4 2 1 When the power cord is connected with normal city power UPS will turn on automatically and go through the procedure of self test about 3 4 sec If test results are O K t...

Page 6: ...ecting a low utility voltage The loads receive normal power The Buck LED would be on when the UPS is connecting a high utility voltage The loads receive normal power 5 3 Auto self test function In normal mode of UPS turn on your computer and push the button on the front panel for self test The UPS will simulate a power outage and transfer your load to the UPS battery If low battery warning sounds ...

Page 7: ...lure Pin4 Common GND of Pin2 Pin5 Pin5 UPS Battery Low Pin6 Turn off UPS Pin7 GND of Pin6 The interface with computer is diagramed as above for your reference Use Pin4 as the common of Pin2 and Pin5 Pin2 and Pin4 will become close loop from open when the utility fails Pin5 and Pin4 will become close loop from open when the battery level is low The UPS will shut down itself when the high level sign...

Page 8: ...at UPS outlets 2 Battery is weak and cannot provide enough capacity Do not operate the UPS and leave the UPS plugged in for 10 hours Then test it again if UPS still cannot provide expected run time battery should be replaced Button on front panel doesn t work 1 The CPU inside UPS is not running correctly 2 Button damaged 1 Push the button for 6 seconds to reset the UPS 2 Unplug line cord and all l...

Page 9: ...ES Recharge Time 90 within 8 hrs 90 within 5 hrs LED ALARM INDICATION Normal In charge GRN LED No Beep Back up Abnormal Input Voltage ORG LED Flashing 2 Beeps 8 sec AbnormalInputFrequency Backup ORG LED Rapid Flashing No Beep Green mode auto off ORG LED flashing 1 Beep 4 sec Auto off after 24 sec Low Battery ORG LED Flashing 4 Beeps sec Battery Replacement RED LED Flashing 8 Beeps sec Over Load Fa...

Page 10: ...s about 5 min German wording ϳ Wenn Sie die Batterien austauschen verwenden Sie bitte die gleiche Anzahl und den gleichen Batterietyp ϳ Werfen Sie niemals die Batterien in das Feuer die Batterien könnten explodieren ϳ Öffnen oder beschädigen Sie nicht die Batterien ausfileβendes Elektrolyt ist schädlich für Haut und Augen ϳ Eine Batterie kann eine Gefahz eines elektrischer Schlages und sehr groβer...

Reviews: