Cosmetic face device BeautyRelax BR-1280
User Manual
20
DŮLEŽITÉ POKYNY POUŽÍVÁNÍ PŘÍSTROJE
•
BeautyRelax Multicare is a new generation device from the category of cosmetic devices designed
for non-invasive skin treatment. This means that none of the parts of the applicator will physically
penetrate under the skin.
•
Non-invasive operation is a prerequisite for the user to use the device in a home environment. The
use of the device does not require the supervision of a trained healthcare professional or cosmetic
aesthetics.
•
BeautyRelax Multicare is certified and complies with all standards imposed on a similar type of
device.
•
The treatment should always be combined with a clear conductive gel or other gel-based cosmetic.
It can be purchased at any pharmacy or health store. It costs a few tens of crowns. Definitely the
cheapest. The more expensive the better. The main purpose of applying a fine layer of gel to the
skin is to increase the conductivity. Radiofrequency waves and fine electric micro-pulses gain better
ability to penetrate the dermis layer, where the structure of collagen and elastic fibers is. If
possible, avoid conductive gel with added flavorings or dyes. Sensitive users' skin may not respond
positively.
•
If you keep the application head on your skin for too long in a matter of seconds and have the
highest level of treatment (radiofrequency, electropulses) set, the device is powerful enough to
cause unpleasant injury to your skin. Therefore, please approach the treatment with the utmost
care and gentleness. If the device is not powerful enough, the desired results cannot be achieved.
•
Try to avoid areas with very thin and sensitive skin, if possible. If there is a smaller layer of
subcutaneous fat, work with lower performance values or avoid this part of the skin completely.
•
You can move the application head on the skin in different ways. Short
strokes or short spot treatment - so-called stamping. The advantage of
stamping is the direct targeting of a specific part of the skin (eg fan-
shaped or tufted wrinkles). Keeping the head in contact with the skin for
too long (radiofrequency) will accumulate energy that will raise the
temperature of the applicator. Therefore, allow a time delay of a few
seconds before applying it to the skin. Increasing the applicator temperature is not a malfunction
of the device, but a concomitant effect of radiofrequency waves for a longer period of time. Start
with a short “tap” on the skin and gradually increase the length.
•
Always clean the application head carefully after each treatment. It is ideal to use clear alcohol for
disinfection. Dry the applicator thoroughly in the final phase. Moisture can oxidize the applicator
contacts. This will greatly increase the life of the application head.
•
No eye protection is required when using red or blue light. However, it is strongly recommended
not to look directly into the light source when in use. Doing so repeatedly and for a long time could
damage your eyes.
•
Should you have any questions or concerns, please contact us at any time:
•
Tel: (+420) 737 196 160 Email: mh@santadria.cz